SECTION 3: CLEARANCES TO COMBUSTIBLES

NOTE: 1. All dimensions are from the surfaces of all tubes, couplings, tees, elbows and crosses.

2.Clearances B, C and D can be reduced by 50% after 7500 mm of tubing downstream from the burner.

3.All measurements are in millimeters.

4.Add 60 mm clearance to uncovered u-tube.

FIGURE 14: U-TUBE, OPPOSITE 45° TILT

B

A

C

D

Model

A

B

C

D

HE15U

200

1370

1500

560

HE20UT

200

1530

1650

560

HE25UT

200

1530

1650

560

HE30UT

250

1630

1860

560

HE35UT

250

1780

1960

560

HE40UT

275

1830

2040

560

HE45UT

300

1880

2110

560

HE50UT

300

1930

2160

560

FIGURE 15: U-TUBE, PROTECTIVE GRILLE

 

A

 

Model

HE15UT

HE20UT

 

 

 

 

 

B

 

D

A

150

150

C

 

 

 

 

 

B

890

970

 

 

 

 

 

 

C

1580

1730

 

 

 

D

760

940

HE25UT

150

970

1730

940

HE30UT

150

1020

1910

1000

HE35UT

150

1170

1980

1090

HE40UT

150

1220

2050

1150

HE45UT

200

1270

2110

1200

HE50UT

200

1380

2210

1300

FIGURE 16: U-TUBE, VENTING

 

E

Radiant tubes

Fan

F

Model

E

F

HE15UT

1000

500

HE20UT

1000

500

HE25UT

1000

500

HE30UT

1000

500

HE35UT

1000

500

HE40UT

1000

500

HE45UT

1000

500

HE50UT

1000

500

9 of 73

Page 15
Image 15
Roberts Gorden HE20UT, HE20ST, HE50DL, HE45UT, HE30DL, HE50ST, HE35UT, HE50UT TUBE, Opposite 45 Tilt, TUBE, Protective Grille