Roberts Gorden HE60DL U-Tube Heater Installation, U-tube Standard Parts List, Cut/Pinch Hazard

Models: HE35UT HE45UT HE40ST HE50DL HE25ST HE50UT HE20ST HE70DL HE30ST HE25UT HE15UT HE40DL HE35ST HE60DL HE15ST HE40UT HE20UT HE50ST HE45ST HE30UT HE30DL

1 82
Download 82 pages 30.77 Kb
Page 31
Image 31

SECTION 7: U-TUBE HEATER INSTALLATION

SECTION 7: U-TUBE HEATER INSTALLATION

WARNING

Cut/Pinch Hazard

Wear protective gear during installation, operation and service.

Edges are sharp.

Failure to follow these instructions can result in injury.

The figures in this section provide a general overview of component placement in a u-tube system. The location of some components such as supports and couplings is crucial for proper installation. Assemble the heater components as shown on Page 27, Figure 22.

For optional reflector configurations for u-tube heaters, see Page 8, Figure 10 through Page 9, Figure 16. Install appropriate suspension hardware, beam clamps, chain or rod at predetermined locations. Adjustments of chain length will provide uniform pitch.

If any step is unclear, please contact Roberts-Gordon LLC at +44 (0)121 506 7700.

7.1 U-tube Standard Parts List

 

 

 

 

 

 

 

 

 

 

Part No.

Description

HE15UT

HE20UT

HE25UT

HE30UT

HE35UT

HE40UT

HE45UT

HE50UT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

033XXXXX

Burner Assembly (Input and Fuel Varies)

1

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

07260001

Fan Package XP1

1

1

1

1

1

-

-

-

 

 

 

 

 

 

 

 

 

 

07260002

Fan Package XP2 (optional)

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

07260003

Fan Package XP3

-

-

-

-

-

1

1

1

 

 

 

 

 

 

 

 

 

 

07260051

Fan Package 1 IP55 (optional)**

1

1

1

1

1

-

-

-

 

 

 

 

 

 

 

 

 

 

07260052

Fan Package 2 IP55 (optional)**

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

07260053

Fan Package 3 IP55 (optional)**

-

-

-

-

-

1

1

1

 

 

 

 

 

 

 

 

 

 

03051100

Burner Tube, 100 mm x 3048 mm

1

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

91409408

Tube, 100 mm x 3048 mm

-

-

-

2

2

2

2

2

 

 

 

 

 

 

 

 

 

 

91409423

Tube, 100 mm x 1524 mm

-

2

2

-

-

-

2

2

 

 

 

 

 

 

 

 

 

 

S5127W

Fan Tube, 100 mm x 3048 mm, with 3048 mm Swirler

-

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

S5134W

Fan Tube, 100 mm x 3048 mm, with 2134 mm Swirler

1

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

01335901

U-tube

1

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

01329600

Standard Coupling Assembly

2

4

4

4

4

4

6

6

 

 

 

 

 

 

 

 

 

 

01329700

Coupling Lock

2

4

4

4

4

4

6

6

 

 

 

 

 

 

 

 

 

 

02750303

Reflector, Aluminium, 2439 mm

4

4

4

6

6

6

8

8

 

 

 

 

 

 

 

 

 

 

027503SS

Reflector, Stainless Steel, 2439 mm (Optional)*

4

4

4

6

6

6

8

8

 

 

 

 

 

 

 

 

 

 

02750800

Reflector End Cap, Aluminium

4

4

4

4

4

4

4

4

 

 

 

 

 

 

 

 

 

 

027508SH

Reflector End Cap, Stainless (Optional)*

4

4

4

4

4

4

4

4

 

 

 

 

 

 

 

 

 

 

03090100

Tube and Reflector Hanger

4

6

6

6

6

6

8

8

 

 

 

 

 

 

 

 

 

 

01318901

Tube Clamp Package (including Nut, Washer & Bolt)

1

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

91908004

Wire Form

2

4

4

4

4

4

6

6

 

 

 

 

 

 

 

 

 

 

03050000

Reflector Support Strap

2

4

4

4

4

4

6

6

 

 

 

 

 

 

 

 

 

 

03020501

U-tube Support Bracket

1

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

E0007576

Bow Shackle***

4

6

6

6

6

6

8

8

 

 

 

 

 

 

 

 

 

 

91107720

U-clip Package (20 Pieces)

2

2

2

2

2

2

2

2

 

 

 

 

 

 

 

 

 

 

91912501

U-bolt M6

2

2

2

2

2

2

2

2

 

 

 

 

 

 

 

 

 

 

C0090B

Nut M6

6

6

6

6

6

6

6

6

 

 

 

 

 

 

 

 

 

 

25 of 73

Page 31
Image 31
Roberts Gorden HE60DL, HE20ST U-Tube Heater Installation, U-tube Standard Parts List, Cut/Pinch Hazard, Edges are sharp