Dump preset (001 on bits 6-4):

00h-2fh – Dump preset A-1through D-8in flash 30h-7eh – Invalid (command will be ignored)

7fh

- Dump preset edit

Dump sequence (011 on bits 6-4):

00h

- Dump upper arpeggiator rhythm/sequence

01h

- Dump lower arpeggiator rhythm/sequence

Figure 20 - Command 04h - Dump block request command

Requests a sequence, patch or patch block, preset or preset block dump from Europa. It responds with one or more write block commands (05h). In the case where multiple presets or patches are dumped, multiple write block commands will be sent – one for each patch or preset. Europa delays 70 milliseconds between each write block command transmitted because of this command. This ensures the patches and/or presets will be properly restored when played back to the Jupiter 6, as this delay is required for writing to Europa’s flash memory.

 

 

 

 

 

 

 

Byte #

Value

Description

 

 

0

05h

Write block – patch, preset, or sequence

 

1

Bitwise

Bit 7

Unused – set to 0

 

 

 

Bits 6-4

Block type to write:

 

 

 

 

000

– Patch

 

 

 

 

001

– Preset

 

 

 

 

010

– Reserved – not valid

 

 

 

 

011

– Arpeggiator step rhythm/sequence

 

 

 

 

100-111 – Not valid - Command will be ignored

 

 

 

Bits 3-0

Unused – set to 0 (other values will invalidate the

 

 

 

 

message and it will be ignored.

 

2-n

Depends on the

See tables below for appropriate patch, preset, or sequence dump

 

 

block type

 

 

 

 

 

 

 

 

 

 

 

Figure 21 - Command 05h - Write block command

Instructs Europa to store a patch, preset, or sequence block in flash or edit buffer. Note that any patch or preset written to flash must delay at least 70 milliseconds afterward to give time for Europa to write to internal flash, otherwise any subsequent command for that time period will be ignored/dropped!

Depending upon byte 1 of the command 05h data stream, one of the following three tables will be applicable:

 

 

 

 

 

 

 

 

 

 

 

 

 

Byte #

Valid

Name

Description

 

 

 

range

 

 

 

 

2

0-47,

Patch number

Place to store patch #0-47 are patch flash positions

 

 

 

126-127

 

A-1through F-8. 126=Lower patch edit,

 

 

 

 

 

127=Upper patch edit (used in WHOLE mode)

 

 

3

0-16

Patch name length

Length of patch’s name. Can be up to 16 ASCII

 

 

 

 

 

characters

 

 

4-19

0-127

Patch name

Patch’s name (in ASCII). This is actually a variable

 

 

 

 

 

length field and is only as long as the data in byte #

 

 

 

 

 

3.

 

 

20

0-127

LFO 1 Rate

Set LFO 1’s rate

 

 

21

0-127

LFO 1 Delay

Set LFO 1’s delay time

 

 

22

0-127

VCO MOD LFO

Set LFO 1’s effect on VCO

 