MIDI Implementation

Data Set (DT1)

Input Parameters

Status

Data Bytes

 

Status

F0H

 

41H,Dev,00H,4EH,12H,aaH,bbH,ccH,ddH, ..., eeH,Sum

F7H

Byte

 

Description

 

 

F0H

 

Status of System Exclusive Message

 

41H

 

Manufacturer ID

 

(Roland)

Dev

 

Device ID

 

 

00H

4EH

Model ID

 

(MMP-2)

12H

 

Command ID

 

(DT1)

aaH

 

Address MSB

 

 

bbH

 

Address MID

 

 

ccH

 

Address LSB

 

 

ddH

 

Data

 

 

:

 

:

 

 

eeH

 

Data

 

 

Sum

 

Check Sum

 

 

F7H

 

EOX

(End of System Exclusive Message)

The message is received under the following condition.

If the device ID on the message is same as that of the receive device, and the address on the message correspond to the specified parameter base address, the received data are stored from the specified parameter base address.

If the interval of received messages is shorter than 25m sec., the MMP-2 can not work the receive message procedure correctly.

The message is transmitted under the following condition.

+————————————————————————————————————————————————————————————————————————+

Start

 

 

Address

Data

Contents and Remarks

==========+=========+===================================================

01 00 00 — 01 Phantom Power 1OFF, ON ——————————+—————————+———————————————————————————————————————————————————

01 01 16 — 46 ATT 1(0dB:40H) —42 — +6dB ——————————+—————————+———————————————————————————————————————————————————

01 02 00 — 01 Phase 1NORMAL, INVERT ——————————+—————————+———————————————————————————————————————————————————

01 03 00 (Reserved) ——————————+—————————+———————————————————————————————————————————————————

01 04 00 — 51 LO—Cut 1TURU,20 — 2.00kHz ——————————+—————————+———————————————————————————————————————————————————

01

05

00

(Reserved)

 

:

 

:

 

 

01

0F

00

(Reserved)

——————————+—————————+———————————————————————————————————————————————————

01 10 00 — 01 Phantom Power 2OFF, ON ——————————+—————————+———————————————————————————————————————————————————

01 11 16 — 46 ATT 2(0dB:40H) —42 — +6dB ——————————+—————————+———————————————————————————————————————————————————

01 12 00 — 01 Phase 2NORMAL, INVERT ——————————+—————————+———————————————————————————————————————————————————

01 13 00 (Reserved) ——————————+—————————+———————————————————————————————————————————————————

01 14 00 — 51 LO—Cut 2TURU,20 — 2.00kHz ——————————+—————————+———————————————————————————————————————————————————

01

15

00

(Reserved)

 

:

 

:

 

 

01

7F

00

(Reserved)

——————————+—————————+———————————————————————————————————————————————————

When the MMP-2 transmit the data on the requested parameter after receiving the Data Request message(RQ1).

See “Data Transfer Address Map” (p. 47) for more details of the transfer parameters.

Data Transfer Address Map

The each address value is expressed as a 7bit hex number.

+————————————————————————————————————————————————————————————————————————+

Address MSB LSB —————————————————————+————————————————+————————————————+————————————————+

Binary

0aaa aaaa

0bbb bbbb

0ccc cccc

7—bit Hex

AA

BB

CC

+————————————————————————————————————————————————————————————————————————+

Parameter Address Block

<Model ID = 00H 4EH>

+————————————————————————————————————————————————————————————————————————+

Start

 

Address

Contents and Remarks

==========+=============================================================

00 00 00 System Parameter ——————————+—————————————————————————————————————————————————————————————

00 01 00 Input Parameter ——————————+—————————————————————————————————————————————————————————————

00 02 00 Effect Parameter (Temp) ——————————+—————————————————————————————————————————————————————————————

00 04 00 Status ——————————+—————————————————————————————————————————————————————————————

00 05 00 Remote Operation ——————————+—————————————————————————————————————————————————————————————

01 00 00 Bulk Data ——————————+—————————————————————————————————————————————————————————————

System Parameter

+————————————————————————————————————————————————————————————————————————+

Start

 

 

Address

Data

Contents and Remarks

==========+=========+===================================================

00 00 00 - 01 Master Clock(*1)INTERNAL, DIGITAL ——————————+—————————+———————————————————————————————————————————————————

00 01 00 - 03 Sampling Frequency(*1) 44.1K,48K,88.2K,96KHz ——————————+—————————+———————————————————————————————————————————————————

00 02 00 - 01 Audio Source(*1)MIC, DIGITAL ——————————+—————————+———————————————————————————————————————————————————

00

03

00

(Reserved)

 

:

 

:

 

 

00

0F

00

(Reserved)

——————————+—————————+———————————————————————————————————————————————————

00 10 00 - 01 USB Driver(*1)VENDER, GENELIC ——————————+—————————+———————————————————————————————————————————————————

00 11 00 - 1F MIDI Device ID(*1)1,,,32 ——————————+—————————+———————————————————————————————————————————————————

00 12 00 - 01 MIDI Level Meter Tx. SwitchOFF,ON ——————————+—————————+———————————————————————————————————————————————————

00

13

00

(Reserved)

 

:

 

:

 

 

00

1F

00

(Reserved)

——————————+—————————+———————————————————————————————————————————————————

00 20 00 - 0F LCD Contrast1,,,16 ——————————+—————————+———————————————————————————————————————————————————

00 21 00 - 02 Peak Level Select-6,-3,0dB ——————————+—————————+———————————————————————————————————————————————————

00 22 00 - 02 Effects RoutingNORM,P IN,P OUT ——————————+—————————+———————————————————————————————————————————————————

00

23

00

(Reserved)

 

:

 

:

 

 

00

7F

00

(Reserved)

——————————+—————————+——————————————————————————————————————————————————— (*1)Read Only Parameters.

Effect Parameters

Basic Address

+————————————————————————————————————————————————————————————————————————+

Start

 

 

Address

Data

Contents and Remarks

==========+=========+===================================================

02

00

20

— 7F

Effects

Patch Name — 1

(ASCII)

:

 

 

:

 

 

:

02

0B

20

7F

Effects

Patch Name —12

——————————+—————————+———————————————————————————————————————————————————

02 0C 10 — 11 Effects Algorithm

Number

 

10H: MIC

MODEL

+

4 BAND

EQ + DYNAMICS

11H: MIC

MODEL

+

DYNAMICS + PLUG IN(Preamp)

——————————+—————————+———————————————————————————————————————————————————

02

0D

00

(Reserved)

 

:

 

:

 

 

02

0F

00

(Reserved)

——————————+—————————+———————————————————————————————————————————————————

02

10

00

7F

Effects Parameters

:

 

 

:

 

03

7F

00

7F

+————————————————————————————————————————————————————————————————————————+

Algorithm 0 (MIC MODELING + 4 BAND EQ + DYNAMICS)

+————————————————————————————————————————————————————————————————————————+

Start

 

 

Address

Data

Contents and Remarks

==========+=========+===================================================

02 10 00 — 01 LINKOFF, ON ——————————+—————————+———————————————————————————————————————————————————

02 11 00 (Reserved) ——————————+—————————+———————————————————————————————————————————————————

02 12 00 — 01 Bypass MODEL 1OFF, ON ——————————+—————————+———————————————————————————————————————————————————

02 13 00 — 01 Bypass MODEL 2OFF, ON ——————————+—————————+———————————————————————————————————————————————————

02 14 00 — 01 Bypass EQ 1OFF, ON ——————————+—————————+———————————————————————————————————————————————————

02 15 00 — 01 Bypass EQ 2OFF, ON ——————————+—————————+———————————————————————————————————————————————————

02 16 00 — 01 Bypass DYN 1OFF, ON ——————————+—————————+———————————————————————————————————————————————————

02 17 00 — 01 Bypass DYN 2OFF, ON ——————————+—————————+———————————————————————————————————————————————————

02

18

00

(Reserved)

 

:

 

:

 

 

02

1F

00

(Reserved)

——————————+—————————+———————————————————————————————————————————————————

02 20 00 — 01 MODEL 1: SWOFF, ON ——————————+—————————+———————————————————————————————————————————————————

02 21

00 — 05

MODEL 1: Input

0,,,5 =

 

DR—20,SmlDy,HedDy,MinCn,Flat,AKGC3K

——————————+—————————+———————————————————————————————————————————————————

02 22

00 — 06

MODEL 1: Output 0,,,6 =

SML.DY,VOC.DY,LRG.DY,SML.CN,LRG.CN,VNT.CN,FLAT

——————————+—————————+———————————————————————————————————————————————————

02 23 34 — 4C MODEL 1: Proximity Effect (0:40H) —12,,,+12 ——————————+—————————+———————————————————————————————————————————————————

02 24 00 — 6B MODEL 1: Timelag0,,,107 = 0,,,3000cm ——————————+—————————+———————————————————————————————————————————————————

02 25 00 — 01 MODEL 2: SWOFF, ON ——————————+—————————+———————————————————————————————————————————————————

02 26

00 — 05

MODEL 2: Input

0,,,5 =

 

DR—20,SmlDy,HedDy,MinCn,Flat,AKGC3K

——————————+—————————+———————————————————————————————————————————————————

02 27

00 — 06

MODEL 2: Output 0,,,6 =

SML.DY,VOC.DY,LRG.DY,SML.CN,LRG.CN,VNT.CN,FLAT

——————————+—————————+———————————————————————————————————————————————————

02 28 34 — 4C MODEL 2: Proximity Effect (0:40H) —12,,,+12 ——————————+—————————+———————————————————————————————————————————————————

02 29 00 — 6B MODEL 2: Timelag0,,,107 = 0,,,3000cm ——————————+—————————+———————————————————————————————————————————————————

02

2A

00

(Reserved)

 

:

 

:

 

 

02

2F

00

(Reserved)

——————————+—————————+———————————————————————————————————————————————————

02 30 00 — 01 EQ 1: SWOFF, ON ——————————+—————————+———————————————————————————————————————————————————

02 31 16 — 46 EQ 1: ATT

(0dB:40H) —42 — +6dB

47

Page 47
Image 47
Roland MMP-2 owner manual Data Transfer Address Map