Roland MMP-2 Trouble Shooting, Symptom, Cause, Remedy, another patch “Resetting Effect Parameters

Models: MMP-2

1 61
Download 61 pages 47.4 Kb
Page 42
Image 42
Trouble Shooting

Trouble Shooting

If the unit doesn’t work the way you think it should, check the items shown in the following table before you assume that there is a malfunction. If the cause of the problem is still unclear, contact your retailer or Roland Corporation’s Customer Service Center.

For other computer-related problems, please read “ReadMe” on the included CD-ROM.

Symptom

Cause

Remedy

 

 

 

Nothing appears on

The display contrast is too

Adjust the contrast of the LCD screen (p. 14).

the LCD screen.

dark or too light.

 

No sound.

The volume is turned

Check the [SENS] controls and the volume

 

down.

levels for connected amplifiers, mixers, and

 

 

other equipment (“Sensitivity (SENS)p. 17).

 

The microphone is not

Check the documentation for the microphone

 

receiving the required

and make the phantom setting if necessary (p.

 

power.

17).

 

The audio input-source

Make settings that match the input jack and

 

settings are different from

standard (“Audio Input Source” p. 26).

 

the actual configuration.

 

 

External malfunction

Check the cables, amp, mixer, and other

 

 

equipment.

The volume of the

You could be using a

Use a connection cable that does not contain a

MIC IN sound is

connection cable that

resistor (such as one from the Roland PCS

too low.

contains a resistor.

series).

The output sound is

The switch setting for the

Set the [OUTPUT LEVEL] switch on the rear

too low or too loud.

output level is not

panel to match the destination device (p. 13).

 

appropriate.

 

Effects are not

The unit is set to OFF or

Check the settings (“Using Effects” p. 19).

applied.

BYPASS.

 

 

 

 

 

RESET was applied.

The RESET function changes the effect

 

 

parameter settings so the most minimal effect is

 

 

produced. Change the parameters or choose

 

 

another patch (“Resetting Effect Parameters

 

 

(RESET)” p. 15).

Changes in system

The power was turned off

When the [ENTER] button is illuminated, it

parameters are not

immediately after making

means there are changes that have not been

saved.

the changes.

saved. Before turning off the power, press the

 

 

[ENTER] button to save such changes (p. 14).

I can't change the

The unit is already

The “DRIVER” setting parameter of MMP-2

“DRIVER” setting

connected to the computer

unit cannot be switched during the USB

parameter of

via USB.

connection of MMP-2 unit and computer exists.

MMP-2 unit.

 

Disconnect once and then change setting.

 

 

(“MMP-2 settings” p. 30).

I changed the USB

The power was not cycled.

A change in the driver takes effect after you

driver, but the

 

switch off the MMP-2’s power, then turn it on

change does not

 

again (“MMP-2 settings” p. 30).

take effect.

 

 

LCD screen

Buttons were pressed in

The temporary distortion of image on LCD after

displays unstable

rough.

rough pressing is not because of malfunction.

image when

 

Please be careful to press buttons in moderate

buttons are pressed

 

pressure.

in rough.

 

 

42

Page 42
Image 42
Roland Trouble Shooting, Symptom, Cause, Remedy, another patch “Resetting Effect Parameters, “MMP-2settings” p