Installation

Connect a PC or home theater control/automation system (if present) to the RS-232 port

RS-232 Controller

on the CL-610; see Figure 3-8.Use a standard, 4-wire RJ-11 telephone cable, wired

Connection

straight-through.

 

For more information about using this connection, refer to Serial Communications on

 

page 53.

 

RJ-11 Male

1

2

3

4

RJ-11 to D-Sub 9-pin Adapter (not included)

Yellow

Yellow

 

Green

Green

 

 

5

4

3

2

1

 

Black

9

8

 

7

6

Black

 

 

 

 

 

Red

 

 

 

 

 

Red

D-Sub 9-pin female

 

 

 

 

 

 

RS-232 Adapter Wiring

D-Sub 9-pin female

4-pin RJ-11

Function

 

 

 

2

2

Transmit Data

 

 

 

3

3

Receive Data

 

 

 

5

1, 4

Ground

 

 

 

1, 4, 6, 7, 8, 9

--

Not Connected

 

 

 

Figure 3-8. RS-232 Control System Connection