Quality

Recording resolution will be determined.

Choose one from Level 1(Low) to Level 8 (High). Level 8 supplies the best resolution

Rate

Determines Frame Rate to be recorded. Frame Rate means the number of screen recorded every second.

Set to 25ips, the system records too many screens per second and play continues intermittently since recording is more detailed. This is appropriate for concentrated monitoring zone setup.

25 ips/ 12.5 ips/ 8.33 ips/ 6.25 ips/ 5 ips/ 2.5 ips/ 1 ips

Note

[Monitor Out]

You are not allowed to set up “25ips” of Rate and Video sized “Full D1” simultane- ously. The system does not support both at once.

PreAlarm

Pre Alarm Section

Event occurred point of time

Records the situation until Alarm is issued.

Off : No recording

5sec/ 10sec/ 20sec/ 30sec : The recording time options before Alarm issue

PostAlarm

Post Alarm Section

Event occurred point of time

Records the situation since Alarm is issued.

Off : No recording

5sec/ 10sec/ 20sec/ 30sec/1min/3min/5min/10min/20min :

To this, the recording time after Alarm issue is set.