Chapter 4 Provisioning the TimeProvider

 

Provisioning Alarms

 

 

<aid>

Description

 

 

SYS

Displays the connectivity status of the Expansion Panel and any

 

alarms associated with the Expansion Panel

 

<pwra> – PWRA-OK PWRA-FAIL

 

<pwrb> – PWRB-OK PWRB-FAIL

 

<expstatus> – OK ALM

 

<extfault> – OK ALM

 

 

IMC

Displays all conditions related to the Information Management module

 

<ioc1comm> – IOC1COMM-OK IOC1COMM-FAIL

 

<ioc2comm> – IOC2COMM-OK IOC2COMM-FAIL

 

 

IOCm

Displays the current setup and conditions related to the system-level

m = 1 2

function of the IOC module

 

<iocstatus> – OK ALM (IOCFAIL)

 

<ioccomm> – IOC1TO2COMM-OK IOC1TO2COMM-FAIL

 

IOC2TO1COMM-OK IOC2TO1COMM-FAIL

 

<imccomm> – IMC1COMM-OK IMC1COMM-FAIL

 

IMC2COMM-OK IMC2COMM-FAIL

 

 

GPS

Displays GPS Input state and any alarm events associated with GPS

 

input

 

<gpsstatus> – OK ALM

 

 

PRS

Displays PRS Input state and any alarm events associated with PRS

 

input

 

<prsstatus> – OK ALM

 

 

INPp

Displays Input state and any alarm events associated with Inputs 1 or 2

p = 1 2

<inpstatus> – OK ALM

 

 

OUTg

Displays output status; this reflects the state of IOCFAIL of the active

g = 1 2 3 4

IOC

 

<outstatus> – OK ALM

 

 

Sample Command

RTRV-COND::IOC:TS1000;

Normal Response

TP-SSU 03-10-24 11:27:28

MTS1000 COMPLD “SYS,PWRA-OK,PWRB-OK,OK,OK”

;

Clearing Alarms

Clearing the Office (Audible) Alarm

Use the following TL1 command to turn off (squelch) the audible office alarm. The office alarm reactivates when a new alarm occurs.

OPR-ACO-ALL:[<tid>]::[<ctag>];