Symmetricom 1000, 1100 manual Eqpt Squelch, Gpsclr, Del, Ssm, Loctim, Eqpt Auto, Timchg

Models: 1100 1000

1 224
Download 224 pages 12.25 Kb
Page 173
Image 173

Chapter 6 Maintaining and Troubleshooting the TimeProvider

Troubleshooting the TimeProvider

Table 6-5. Event Codes (Continued)

Event ID

Keyword

AID

Default Value/

Description of Values

Description

TYPE

Keyword

 

 

 

 

 

 

 

FREEFLT

Indicates if the Output

EQPT

SQUELCH

ON – In fault mode, generate

 

Fault is issued when

 

 

outputs based on system SSM

 

the local oscillator

 

 

AIS – In fault mode, generate

 

enters Free-Run

 

 

AIS outputs

 

mode.

 

 

SQUELCH – In fault mode,

 

 

 

 

outputs are turned off

 

 

 

 

 

GPSCLR

The time, in seconds,

EQPT

5 s

0 to 1000 s

DEL

after a cleared GPS

 

 

 

 

fault can be used.

 

 

 

 

 

 

 

 

GPSFLTDEL

Time, in seconds,

EQPT

1 second

1 to 1000 s

 

before a GPS fault

 

 

 

 

indicated it is not valid

 

 

 

 

 

 

 

 

HOLDFLT

Indicates if the Output

EQPT

ON

ON – In fault mode, generate

 

Fault is issued when

 

 

outputs based on system

 

the local oscillator

 

 

SSM

 

enters Holdover mode

 

 

AIS – In fault mode, generate

 

 

 

 

AIS outputs

 

 

 

 

SQUELCH – In fault mode,

 

 

 

 

outputs are turned off

 

 

 

 

 

INPREF

Indicates if the system

T1

PRS

PRS – PRS input is selected

 

automatically selects

 

 

as reference

 

another reference

 

 

INP1 – INP1 is selected as

 

input. Operator has

 

 

reference

 

enabled the selected

 

 

INP2 – INP2 is selected as

 

reference input

 

 

reference

 

(REFMODE must be

 

 

 

 

set to FORCED)

 

 

 

 

 

 

 

 

LOCTIM

The local system time

EQPT

(00)-00

(hh) – hours offset ±12

 

offset has changed

 

 

mm – minutes offset 00 to 59

 

 

 

 

 

 

 

 

 

REFMODE

Indicates if the system

EQPT

AUTO

AUTO – System uses

 

reference can be

 

 

QLEVEL and Priority to select

 

selected automatically

 

 

the system reference

 

or by the user

 

 

FORCED – User selects the

 

 

 

 

system reference. If the

 

 

 

 

selected reference fails, this

 

 

 

 

value reverts to AUTO mode

 

 

 

 

 

TIMCHG

The system time has

EQPT

hh-mm-ss

hh – hours (24-hour clock)

 

been changed

 

 

mm – minutes

 

 

 

 

ss – seconds

 

 

 

 

 

097-58001-02 Revision G – April 2008

TimeProvider User’s Guide 173

Page 173
Image 173
Symmetricom 1000, 1100 manual Eqpt Squelch, Gpsclr, Del, Ssm, Loctim, Eqpt Auto, Timchg