Chapter 4 Provisioning the TimeProvider

Provisioning Alarms

Provisioning Alarms

This section describes how you provision and manage alarms in the TimeProvider. There are TL1 commands that allow you to:

Provision individual alarm levels

Provision system-wide alarm levels

Display current alarm settings

Display current alarms

Display alarm status

Alarms are displayed on the IMC or IMC/TPIU LEDs; they also appear on the relay contact closures on the Input module.

Provisioning the Alarm Levels

Use the SET-ATTR command to set the alarms associated with the IMC and IOC. You can use this command to reset all alarm levels to the factory default values, and to allow the TimeProvider to escalate alarms. Table 4-3lists the alarms, a brief description of each alarm, and it’s default parameters.

SET-ATTR:[<tid>]:<aid>:[<ctag>]::<keyword>[=<value>];

This command has a default access level of ADMIN.

<aid>

<keyword>

<value>

Description

 

 

 

 

SYS

ELEVTIME

ENABLE DISABLE (default)

Allow alarms to escalate from

 

 

 

Minor to Major and from

 

 

 

Major to Critical

 

 

 

 

 

FACTORY

 

Set the alarm levels to factory

 

 

 

default values

 

 

 

 

<aid>

<keyword>

<value>

Description

 

 

 

 

SYS

Alarm ID

NR = Not Reported

See the definitions for the

IMC

 

NA = A non-alarm event

Alarm ID in the following table

IOC

 

MN = Minor alarm

 

PRS

 

MJ = Major alarm

 

INPp (p = 1 2)

 

CR = Critical alarm

 

 

 

CLEAR = Clears an active

 

 

 

alarm; if the condition persists,

 

 

 

then the alarm is reissued

 

 

 

 

 

126 TimeProvider User’s Guide

097-58001-02 Revision G – April 2008

Page 126
Image 126