Chapter 4 Provisioning the TimeProvider

Provisioning Retimer Parameters

Autonomous Message

TP-SSU 03-10-24 11-09-12 A 1189 REPT EVT

“OUTA,EQPT:NA,OUTSTATE,NSA,03-10-24 11-09-12:\"OUTPUT

GROUP STATE HAS CHANGED,DISABLE\””

;

Provisioning the LBO

Use the ED-SYNC command to set the line build-out (LBO) for each port (1 or 2) on the Retimer module.

ED-SYNC:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;

This command has a default access level of ADMIN.

<aid>

<keyword>

<value>

Description

Default value

 

 

 

 

 

RTMg[-p]

RTMLBO

0

Sets the line build-out

0

g = A B C D

 

 

length to 0 to 133 ft

 

p= 1 2

 

 

(0 to 40 m)

 

Note: The RTM-

 

 

 

 

 

1

Sets the line build-out

 

LBO parameter is

 

 

 

 

length to 133 to 266 ft

 

valid only for T1

 

 

 

 

 

(40 to 81 m)

 

signals; for the

 

 

 

 

 

 

 

E1 Retimer, the

 

2

Sets the line build-out

 

IPNV (Invalid

 

 

length to 266 to 399 ft

 

Parameter)

 

 

(80 to 121 m)

 

DENY code is

 

 

 

 

 

3

Sets the line build-out

 

returned.

 

 

 

 

 

length to 399 to 533 ft

 

 

 

 

(121 to 162 m)

 

 

 

 

 

 

 

 

4

Sets the line build-out

 

 

 

 

length to 533 to 650 ft

 

 

 

 

(162 to 198 m)

 

 

 

 

 

 

Sample Command

ED-EQPT::RTMA-1:TS1000::RTMLBO=2;

This command sets the line build-out length for port 1 in Retimer group A to 266 to 399 ft (80 to 121 m).

Autonomous Message

TP-SSU 03-10-24 11-09-12 A 1189 REPT EVT

“RTMA,EQPT:NA,OUTSTATE,NSA,03-10-24 11-09-12:\"LBO HAS CHANGED,2\””

;

097-58001-02 Revision G – April 2008

TimeProvider User’s Guide 121

Page 121
Image 121
Symmetricom 1000, 1100 manual Provisioning the LBO, Rtmlbo