Chapter 4 Provisioning the TimeProvider

 

 

 

 

 

Provisioning Alarms

Table 4-3. Alarm Conditions and Defaults (Continued)

 

 

 

 

 

 

 

 

 

 

 

 

Description of Alarm

Possible

Error

Error

Default Level

 

 

 

Alarm ID

Alarm

Delay

Delay

 

 

Condition

SSU

SUB

 

Levels

Default

Editable?

 

 

Mode

Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<aid> = INP1 or INP2

 

 

 

 

 

 

 

 

 

 

INPDISQ

Specified input has

MN MJ

FLT

Yes

MN

MN

 

been disqualified or

CR

DELAY

 

 

 

 

qualified as a possible

 

 

 

 

 

 

system reference.

 

 

 

 

 

 

 

 

 

 

 

 

INPAIS

The specified input is

MN MJ

IMMED

No

MN

MN

 

receiving an Alarm

CR

 

 

 

 

 

Indication Signal.1

 

 

 

 

 

INPLOS

The specified input has

MN MJ

IMMED

No

MN

MN

 

Loss of Signal.1

CR

 

 

 

 

INPOOF

The specified input is

MN MJ

IMMED

No

MN

MN

 

receiving an Out of

CR

 

 

 

 

 

Frame signal.1

 

 

 

 

 

INPFRQ

Specified input port’s

NR NA

IMMED

No

MN

NR

 

calculated received

MN MJ

 

 

 

 

 

frequency exceeds the

CR

 

 

 

 

 

pull-in range of the

 

 

 

 

 

 

LO.This alarm condition

 

 

 

 

 

 

disqualifies the input as

 

 

 

 

 

 

a possible reference.2

 

 

 

 

 

INPPHASE

Specified input port’s

NR NA

IMMED

No

MN

MN

 

phase measurement

MN MJ

 

 

 

 

 

exceeds usable value.

CR

 

 

 

 

 

 

 

 

 

 

 

INPQL

The received SSM is of

NR NA

IMMED

No

MN

MN

 

lesser quality than the

MN MJ

 

 

 

 

 

provisioned QLEVEL for

CR

 

 

 

 

 

a specified input. This

 

 

 

 

 

 

alarm occurs when you

 

 

 

 

 

 

provision the input’s

 

 

 

 

 

 

QLEVEL below the

 

 

 

 

 

 

quality level of the LO.

 

 

 

 

 

 

 

 

 

 

 

 

EXDSC

Input has had excessive

NR NA

IMMED

No

MN

MN

 

discontinuities, indicated

MN MJ

 

 

 

 

 

by more than 3 signal

CR

 

 

 

 

 

faults (OOF, BPV, CRC,

 

 

 

 

 

 

or AIS) within a 5-minute

 

 

 

 

 

 

window. The alarm

 

 

 

 

 

 

clears when the 5-

 

 

 

 

 

 

minute window contains

 

 

 

 

 

 

less than 3 signal faults.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

097-58001-02 Revision G – April 2008