Chapter 6 Maintaining and Troubleshooting the TimeProvider

Troubleshooting the TimeProvider

Table 6-7. Alarm Codes (Continued)

 

 

AID

Service

 

Alarm Level

 

Event ID

Description

 

 

 

 

 

 

 

 

 

 

TYPE

Affecting

SSU

 

PRR

 

SUB

 

 

 

 

 

 

 

 

Mode

 

Mode

 

Mode

 

 

 

 

 

 

 

 

 

INPFRQ

The specified input port’s

T1

NSA

MN

 

MN

 

MN

 

calculated received frequency

 

 

 

 

 

 

 

 

exceeds the pull-in range of the

 

 

 

 

 

 

 

 

LO. This alarm disqualifies an

 

 

 

 

 

 

 

 

input as a system reference.

 

 

 

 

 

 

 

 

Once set, this alarm clears

 

 

 

 

 

 

 

 

when the input frequency is

 

 

 

 

 

 

 

 

within the defined pull-in range

 

 

 

 

 

 

 

 

limits.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INP

The specified input port has an

T1

NSA

MN

 

MN

 

MN

PHASE

excessive phase measurement

 

 

 

 

 

 

 

 

that disqualifies it from being

 

 

 

 

 

 

 

 

used.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXDSC

The specified input has had

T1

NSA

MN

 

MN

 

MN

 

excessive discontinuities,

 

 

 

 

 

 

 

 

indicated by more than 3 signal

 

 

 

 

 

 

 

 

faults of the same type within a

 

 

 

 

 

 

 

 

5-minute window. The alarm

 

 

 

 

 

 

 

 

clears when the window

 

 

 

 

 

 

 

 

contains less than 3 alarms of

 

 

 

 

 

 

 

 

the same type.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FFOFF

The specified input port has

T1

NSA

MN

 

MN

 

MN

 

exceeded the Fractional

 

 

 

 

 

 

 

 

Frequency Offset threshold.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MTIE

The specified input port has

T1

NSA

MN

 

MN

 

MN

 

exceeded at least 1 of the MTIE

 

 

 

 

 

 

 

 

alarm thresholds.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AID = INP1 or INP2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPDISQ

The specified input port has

T1

NSA

MN

 

MN

 

MN

 

been disqualified as a possible

 

 

 

 

 

 

 

 

system reference. The fault

 

 

 

 

 

 

 

 

condition must be continuously

 

 

 

 

 

 

 

 

present for the FLTDELAY

 

 

 

 

 

 

 

 

period before disqualifying the

 

 

 

 

 

 

 

 

input as a possible reference.

 

 

 

 

 

 

 

 

Once set, this alarm clears

 

 

 

 

 

 

 

 

when the input is fault-free for

 

 

 

 

 

 

 

 

the CLRDELAY period.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

097-58001-02 Revision G – April 2008

TimeProvider User’s Guide 181

Page 181
Image 181
Symmetricom 1000, 1100 manual Specified input has had