Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider
170 TimeProvider User’s Guide 097-58001-02 Revision G – April 2008
XFEROK Transfer of the IMC
Istate to the IOC,
transfer of the IOC
Istate to the IMC, or
transfer of the IOC
Istate to the redundant
IOC was successful
EQPT n/a n/a
IOC Event Codes
CLKTYPE The specified IOC
clock has been set to
the specified value.
This value is used to
define the IOCs pull-in
range and SSM
generation in Holdover
mode
EQPT TYPEI ST3E | TYPE I
ST2 | TYPE II
INPREF The specified input
has been set as the
system reference
EQPT PRS PRS | INP1 | INP2
IOCMODE The specified IOC has
become Active EQPT ACTIVE ACTIVE | STANDBY
IOCSTATE The specified IOC has
been inserted into the
system. The IOC is
automatically placed
In-Service
EQPT INSRV INSRV – In service
The specified IOC has
been taken out of
service. The IOC can
no longer generate
alarms, be
provisioned, or accept
queries
OOSRV – Out of service
Communication
between the IMC and
IOC has failed
COMMFLT –
Communications fault
The specified IOC has
been removed from
the system
UNEQUIPPED
Table 6-5. Event Codes (Continued)
Event ID Keyword
Description AID
TYPE Default Value/
Keyword Description of Values