Chapter 4 Provisioning the TimeProvider

System Commands

Normal Response Format

<cr><lf><lf>

^^^sid^date^time<cr><lf>

M^ctag^COMPLD<cr><lf>

^^^”<aid>:<keyword>,<value>”<cr><lf>

;

Restarting the TimeProvider

Use the INIT-SYS command to reset the specified module or to clear all information stored in non-volatile memory. All users logged in to the TimeProvider are logged out and the user list is cleared.

Caution: This command causes the local oscillator in the specified IOC to enter the Warm-up mode; the outputs remain in the holdover mode until the local oscillator locks on to the input reference signal.

All SYS parameters are reset, including the entire user list. You must create a new security-level user after issuing this command with the SYS:FACTORY aid and keyword.

INIT-SYS:[<tid>]:<aid>:[<ctag>]::<keyword>;

This command has a default access level of ADMIN.

<aid>

<keyword>

Description

 

 

 

SYS

FACTORY

Resets the SID, security, communication ports, and

 

 

alarm settings to factory defaults (see Appendix A,

 

 

Factory Default Values)

 

 

 

IMC

RESET

Performs a soft reset on the card and clears all alarms.

IOCm

 

Does not affect the SID, security, communication

m = 1 2

 

ports, and alarm settings

 

 

 

Sample Command

INIT-SYS::IOC1:::RESET;

Autonomous Message

TP-SSU 03-10-24 11:31:52 A 1193 REPT EVT

“IOC,EQPT:MN,RESET,NSA,03-10-24 11-30-42:\”MODULE HAS BEEN RESET\””

;

140 TimeProvider User’s Guide

097-58001-02 Revision G – April 2008