Chapter 4 Provisioning the TimeProvider

System Commands

Normal Response

TP-SSU 03-10-24 11:28:02

M 2 COMPLD “INP1,T1:MJ,ALM,NSA,03-10-24 11-26-47”

;

Normal Response Format

<cr><lf><lf>

^^^sid^date^time<cr><lf>

M^<ctag>^COMPLD

^^^”<aid>,<aidtype>:ntfcncde,condtype,srveff,ocrdat,ocrtim

<:condscr>”<cr><lf>*

;

where * indicates zero or more of the preceding element

Displaying the Configuration of the TimeProvider

Use the following TL1 command to display the current equipment parameters. You can display the parameters for the following components: SYS, COM, IOC, GPS, PRS, INP, and OUT.

RTRV-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>;

This command has a default access level of USER.

Response

Description

 

 

<aid>

The access identifier for the equipment component (SYS, COM,

 

IMC, IOC, GPS, PRS, INP, or OUT)

 

 

<keyword>

The specific equipment parameter you requested See the

 

TimeProvider TL1 Reference Guide for details on the available

 

keywords.

 

 

<value>

The current setting of the requested equipment parameter.

 

 

Sample Command

RTRV-EQPT::IOC1:TS1000::IOCMODE;

This command causes the TimeProvider to return the current operating mode for IOC1.

Normal Response

TP-SSU 03-10-24 11:30:42

MTS1000 COMPLD “IOC1:IOCMODE,ACTIVE”

;

097-58001-02 Revision G – April 2008

TimeProvider User’s Guide 139

Page 139
Image 139