Symmetricom 1100, 1000 manual IMC Codes, IOC1 Codes, IOC2 Codes

Models: 1100 1000

1 224
Download 224 pages 12.25 Kb
Page 174
Image 174

Chapter 6 Maintaining and Troubleshooting the TimeProvider

Troubleshooting the TimeProvider

Table 6-6describes the alarm codes and their set and clear conditions.

Table 6-6. Set and Clear Conditions for Alarms

Alarm ID

Set Alarm Conditional Description

Clear Alarm Conditional Description

 

 

 

 

SYS Codes

 

 

 

 

COMPAT

System components are incompatible

System components are compatible

 

 

 

EXPFAIL

Expansion connectivity failed

Expansion connectivity restored

 

 

 

PWRA

Power A Failed

Power A Restored

 

 

 

PWRB

Power B Failed

Power B Restored

 

 

 

EXTALM1

External Alarm 1 set

External Alarm 1 cleared

 

 

 

EXTALM2

External Alarm 2 set

External Alarm 2 cleared

 

 

 

IOC1EQPT

IOC1 removed from the shelf

IOC1 reinstalled

 

 

 

IOC2EQPT

IOC2 removed from the shelf

IOC2 reinstalled

 

 

 

 

IMC Codes

 

 

 

 

IOC1COMM

IMC to IOC1 communication failed

IMC to IOC1 communication established

 

 

 

IOC2COMM

IMC to IOC2 communication failed

IMC to IOC2 communication established

 

 

 

IMCFAIL

Summary alarm of BIST faults

 

 

 

 

 

IOC1 Codes

 

 

 

 

IOC1COMM

IOC1 to IMC communication failed

IOC1 to IMC communication established

 

 

 

IOC1TO2COMM

IOC1 to IOC2 communication failed

IOC1 to IOC2 communication established

 

 

 

IOCFAIL

IOC hardware failure

IOC hardware restored

 

 

 

BTBCKUP

BesTime backup reference disqualified

BesTime backup sources qualified

 

 

 

CLKBRDG

Clock is in Bridging mode

Clock exited Bridging mode

 

 

 

CLKFREE

Clock entered Free-run mode

Clock exited Free-run mode

 

 

 

CLKHOLD

Clock entered Holdover mode

Clock exited Holdover mode

 

 

 

CLKWARM

Clock entered Warm-up mode

Clock exited Warm-up mode

 

 

 

SYNTHEOR

Output generator exceeded pull-in

Output generator within pull-in range

 

range

 

 

 

 

 

IOC2 Codes

 

 

 

 

IOC2COMM

IOC2 to IMC communication failed

IOC2 to IMC communication established

 

 

 

IOC2TO1COMM

IOC2 to IOC1 communication failed

IOC2 to IOC1 communication established

 

 

 

IOCFAIL

IOC hardware failure

IOC hardware restored

 

 

 

 

 

 

174 TimeProvider User’s Guide

097-58001-02 Revision G – April 2008

Page 174
Image 174
Symmetricom 1100, 1000 manual IMC Codes, IOC1 Codes, IOC2 Codes