Symmetricom 1100, 1000 manual Using Alarm Codes to Troubleshoot

Models: 1100 1000

1 224
Download 224 pages 12.25 Kb
Page 176
Image 176

Chapter 6 Maintaining and Troubleshooting the TimeProvider

Troubleshooting the TimeProvider

Table 6-6. Set and Clear Conditions for Alarms (Continued)

Alarm ID

Set Alarm Conditional Description

 

Clear Alarm Conditional Description

 

 

 

 

INPTRR

Tip/ring reversal on CC input

 

Tip/ring connection correct on CC input

 

 

 

 

EXDSC

Excessive discontinuity fault

 

Excessive discontinuity cleared

 

 

 

 

MTIE

MTIE exceeded threshold

 

MTIE within threshold

 

 

 

 

 

OUT[g] Codes

 

 

 

 

 

OUTFAIL

Output fault

 

Output fault cleared

 

 

 

 

SYNTHEOR

Output generator exceeds pull-in range

 

Output generator within pull-in range

 

 

 

 

SYNTHFAIL

Output generator failed

 

Output generator restored

 

 

 

 

 

E422[g] Codes

 

 

 

 

 

E422EQPT

EIA-422 Output module is unequipped

 

EIA-422 Output module is equipped

 

 

 

 

E422FAULT

EIA-422 Output module has a fault

 

EIA-422 Output module fault cleared

 

 

 

 

 

RTMg[-p] Codes

 

 

 

 

 

RTMEQPT

Retimer module is unequipped

 

Retimer module is equipped

 

 

 

 

S1LOS

Side 1 LOS fault

 

Side 1 LOS fault cleared

 

 

 

 

S2LOS

Side 2 LOS fault

 

Side 2 LOS fault cleared

 

 

 

 

EXSLIP

Slip rate threshold exceeded

 

Slip rate within threshold

 

 

 

 

RTMFAULT

Retimer module has a fault

 

Retimer module fault cleared

 

 

 

 

Using Alarm Codes to Troubleshoot

Table 6-7lists the alarm codes generated by the TimeProvider. Unless specified, each alarm has a default Error Delay of Immediate, and you cannot edit the Error Delay.

Table 6-7. Alarm Codes

 

 

 

AID

Service

 

Alarm Level

 

Event ID

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

TYPE

Affecting

SSU

 

PRR

 

SUB

 

 

 

 

 

 

 

 

 

 

Mode

 

Mode

 

Mode

 

 

 

 

 

 

 

 

 

 

 

 

AID = SYS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMPAT

System components (hardware

EQPT

NSA

MJ

 

MJ

 

MJ

 

or software) are incompatible.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

176 TimeProvider User’s Guide

097-58001-02 Revision G – April 2008

Page 176
Image 176
Symmetricom 1100, 1000 manual Using Alarm Codes to Troubleshoot