Chapter 6 Maintaining and Troubleshooting the TimeProvider

Troubleshooting the TimeProvider

Table 6-6. Set and Clear Conditions for Alarms (Continued)

Alarm ID

Set Alarm Conditional Description

Clear Alarm Conditional Description

 

 

 

BTBCKUP

BesTime backup reference disqualified

BesTime backup sources qualified

 

 

 

CLKBRDG

Clock entered Bridging mode

Clock exited Bridging mode

 

 

 

CLKFREE

Clock entered Free-run mode

Clock exited Free-run mode

 

 

 

CLKHOLD

Clock entered Holdover mode

Clock exited Holdover mode

 

 

 

CLKWARM

Clock entered Warm-up mode

Clock exited Warm-up mode

 

 

 

SYNTHEOR

Output generator exceeded pull-in

Output generator within pull-in range

 

range

 

 

 

 

 

GPS Codes

 

 

 

 

ANTCOMM

GPS antenna communication fault

GPS antenna comm fault cleared

 

 

 

GPSPOS

GPS antenna position unknown

GPS antenna position known

 

 

 

GPSPWR

GPS power fault

GPS power fault cleared

 

 

 

GPSSYS

GPS system fault

GPS system OK

 

 

 

GPSTRK

GPS is not tracking satellites

GPS is tracking satellites

 

 

 

INPDISQ

GPS input is disqualified

GPS input is enabled

 

 

 

INPLOS

LOS fault

LOS fault cleared

 

 

 

INPFRQ

Frequency threshold exceeded

Frequency within threshold

 

 

 

INPPHASE

Phase error exceeded threshold

Phase error within threshold

 

 

 

EXDSC

Excessive discontinuity fault

Excessive discontinuity cleared

 

 

 

FFOFF

FFOFF exceeded threshold

FFOFF within threshold

 

 

 

MTIE

MTIE exceeded threshold

MTIE within threshold

 

 

 

TPIUSIG

TPIU signal fault

TPIU signal fault cleared

 

 

 

 

PRS and INP[p] Codes

 

 

 

INPDISQ

Input disqualified as possible reference

Input qualified as possible reference

 

 

 

INPAIS

AIS fault

AIS fault cleared

 

 

 

INPLOS

LOS fault

LOS fault cleared

 

 

 

INPOOF

OOF fault

OOF fault cleared

 

 

 

INPFRQ

Frequency threshold exceeded

Frequency within threshold

 

 

 

INPPHASE

Phase error exceeded threshold

Phase error within threshold

 

 

 

INPQL

Quality Level (SSM) exceeded

Quality Level (SSM) within threshold

 

threshold

 

 

 

 

097-58001-02 Revision G – April 2008

TimeProvider User’s Guide 175

Page 175
Image 175
Symmetricom 1000, 1100 manual GPS Codes, PRS and INPp Codes