Chapter 3 Installing the TimeProvider

Installing Connections to the Ethernet Port

Network Connection

You can use a network connection for routine monitoring and control of the TimeProvider from a remote site. Perform the following steps to connect the TimeProvider to a network.

1.Connect one end of an RJ-45 cable to the LAN outlet. Connect the other end of the cable to the LAN connector on the TimeProvider.

2.To connect the PC or laptop to the LAN, connect one end of the RJ-45 cable to the Ethernet port of the PC or laptop. Connect the other end of the cable to the LAN outlet.

3.Use a remote monitoring software application such as SynCraft or TimePictra to connect to and monitor the TimeProvider. See Appendix B, CRAFT Software Reference, for more information on installing and using SynCraft.

Table 3-8lists the Ethernet communications port signal connections.

Table 3-8. Ethernet Communications Port Signal Connections

Name

Pin

 

 

TX+ (Positive Side of Transmitted Data)

1

 

 

TX- (Negative Side of Transmitted Data)

2

 

 

RX+ (Positive Side of Received Data)

3

 

 

Not Used

4

 

 

Not Used

5

 

 

RX- (Negative Side of Received Data)

6

 

 

Not Used

7

 

 

Not Used

8

 

 

097-58001-02 Revision G – April 2008