Chapter 4 Provisioning the TimeProvider

Provisioning the Input Reference

Provisioning the Input Reference

You need to know the following information about the input reference signal before you can provision the Input Reference signals:

Input selection mode

Interface type

Frame type/frequency

Quality level

Priority level

SSMs and bit position

CRC

Setting the Input State

Use the ED-EQPT command to provision the inputs to the TimeProvider. You can enable, disable, or place an input in Monitor mode (where the input is monitored, but cannot be selected as the system reference).

ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;

This command has a default access level of ADMIN.

<aid>

<keyword>

<value>

Description

Default value

 

 

 

 

 

PRS

INSTATE

ENABLE

Enables the specified input

ENABLE

INPp (p = 1 2)

 

 

 

GPS = DISABLE

 

MONITOR

Places the specified input in

GPS

 

 

 

 

Monitor Only mode

 

 

 

 

 

 

 

 

 

 

 

 

DISABLE

Disables the specified input

 

 

 

 

 

 

Sample Command

ED-EQPT::INP1:TS1000::INSTATE=MONITOR;

This command places Input 1 in the Monitor mode.

Autonomous Message

TP-SSU 03-10-24 10:44:21 A 1178 REPT EVT

“INP1,T1:NA,INSTATE,NSA,03-10-24 10-44-21:\"INPUT STATE HAS CHANGED,MONITOR\””

;

108 TimeProvider User’s Guide

097-58001-02 Revision G – April 2008

Page 108
Image 108
Symmetricom 1100 Provisioning the Input Reference, Setting the Input State, PRS Instate Enable, GPS = Disable, Monitor