Chapter 4 Provisioning the TimeProvider

Starting the TimeProvider for the First Time

Powering Up the TimeProvider

To power up the TimeProvider, perform one of the following tasks, as appropriate:

Connect the power leads from the power supply (see Making Power Connections, on page 61)

Install the fuse in the fuse panel Turn on the power supply

LED Indications on Power-up

The LEDs on the IMC, IOC, and TPIU (if present) illuminate in the following sequence:

The LEDs on the TPIU remain off until the Master shelf has completed its power-on testing and the GPS input has been enabled. The TPIU and Antenna Power LEDs light green and the Antenna Signal LED lights red. When the Master shelf completes its power-on testing, the Antenna Signal LED lights green, indicating that the TPIU is receiving a valid signal from the antenna.

Logging In for the First Time

To log in to the TimeProvider for the first time, you must create a username and password using the TL1 commands described below. Once you create a username and password, you can connect to the TimeProvider using the SynCraft application as described in Using SynCraft, on page 102, or using the TL1 commands in this section.

1.Connect a straight-through DB-9-to-DB-9 serial cable to the local Craft port located on the front panel of the IMC or IMC/TPIU card. Connect the other end of the cable to a computer.

2.Start a terminal emulation program such as HyperTerminal or ProComm Plus. Configure the program for 9600 baud, 8 data bits, No parity, and 1 stop bit, which are the TimeProvider’s default communication parameter values.

3.Type ; (semicolon). If the TimeProvider responds with a Deny response, you have established communications. If you do not receive the Deny response, check the connections, the cable, and the program settings.

Changing the Echo Mode

To view the keystrokes you enter in the terminal emulation program, you need to set the Echo mode to Enable. Issue the following command:

ED-EQPT::COML:TS1000::ECHO=ENABLE;

The TimeProvider responds with:

TIMEPROVIDER 07-08-24 10:15:04

MTS1000 COMPLD

;

097-58001-02 Revision G – April 2008

TimeProvider User’s Guide 89

Page 89
Image 89
Symmetricom 1000, 1100 manual Logging In for the First Time, Powering Up the TimeProvider, LED Indications on Power-up