Chapter 4 Provisioning the TimeProvider

Provisioning Alarms

<aid>

<keyword>

<value>

Description

Default value

 

 

 

 

 

SYS

GPSCLRDEL

0 to 1000 s

Sets the time delay to

5

(cont’d)

 

 

declare GPS is valid after

 

 

 

 

an alarm condition clears

 

 

 

 

 

 

 

GPSFLTDEL

1 to 1000 s

Sets the time delay before a

1

 

 

 

GPS fault is declared

 

 

 

 

 

 

Sample Command

ED-SYNC::SYS:TS1000::CLRDELAY=5;

This command declares a faulted input to be valid five seconds after the alarm condition has cleared.

Autonomous Message

TP-SSU 03-10-24 11:18:00 A 1192 REPT EVT

“SYS,EQPT:NA,CLRDELAY,NSA,03-10-24 11-18-00:\"INPUT CLEAR DELAY HAS CHANGED\””

;

Retrieving Current Alarm Settings

You can display the current settings for any alarm using the RTRV-ATTR command.

RTRV-ATTR:[<tid>]:<aid>:[<ctag>][::<keyword>];

This command always has an access level of USER.

<aid>

<keyword>

Description

 

 

 

SYS

ELEVTIME

ENABLE DISABLE

 

 

 

SYS

Alarm ID

The Alarm ID is described in Provisioning

IMC

 

the Alarm Levels, on page 126

IOC

 

 

PRS

 

 

INPp (p = 1 2)

 

 

 

 

 

ALL (or null)

ALL (or null)

Returns all of the alarm attributes

 

 

 

097-58001-02 Revision G – April 2008

TimeProvider User’s Guide 131

Page 131
Image 131
Symmetricom 1000 Retrieving Current Alarm Settings, SYS Gpsclrdel, Aid Keyword Description, SYS Elevtime Enable Disable