Chapter 4 Provisioning the TimeProvider

Provisioning Alarms

Response Format

<cr><lf><lf>

sid date time<cr><lf>

Mctag COMPLD<cr><lf>

“<aid>:event id,alarm level”<cr><lf> “<aid>:event id,alarm level”<cr><lf>

.

.

“<aid>:event id,alarm level”<cr><lf>

;

Field

Description

 

 

<aid>

The aid specified in the command

 

 

event id

The identifier of the alarm whose level is displayed

 

 

alarm level

The value indicates the alarm level that is generated by an alarm

 

event:

 

NR = Not Reported

 

NA = A non-alarm event

 

MN = Minor alarm

 

MJ = Major alarm

 

CR = Critical alarm

 

 

Sample Command

RTRV-ATTR::SYS:TS1000;

This command causes the TimeProvider to return the alarm levels associated with all system-level alarms.

Normal Response

TP-SSU 03-10-24 11:21:20

MTS1000 COMPLD "SYS:IOC1EQPT,NA" "SYS:IOC2EQPT,NA" "SYS:PWRA,MJ" "SYS:PWRB,MJ" "SYS:EXTALM1,MJ" "SYS:EXTALM2,CR"

"SYS:EXPFAIL,MJ"

;

Retrieving Current Alarms

You can display the current active alarms using the RTRV-ALM command.

RTRV-ALM:[<tid>]:<aid>:[<ctag>];

132 TimeProvider User’s Guide