Chapter 3 Installing the TimeProvider

Making Connections

Making Communications Connections

The TimeProvider has one Ethernet and two serial ports available. The Ethernet connector is on the front panel of the Front Access shelf and on the rear panel of the Rear Access shelf; the local Craft serial port is on the faceplate of the IMC or IMC/TPIU, and the Remote port is on the shelf.

The local Craft serial port is used for control and monitoring of the unit, and is configured as a DCE device. The Remote port can be used for remote dial-in connection to the unit, and is configured as a DTE device.

Connecting to the Local Craft and Remote Serial Ports

To connect a device to the local Craft or the Remote serial port, perform the following steps:

1.Connect a 9-pin serial cable to the desired port.

2.Connect the other end of the cable to the serial port of the PC or terminal device. Use the procedure described in Starting the TimeProvider for the First Time, on page 88, to connect to the TimeProvider.

The default settings for the local Craft serial port are DCE, 9600 Baud, 8 bits, no parity, 1 stop bit, echo on, and handshaking disabled. Table 3-7lists the signal connections for the serial ports.

Table 3-7. Connector Pinouts for the Serial Ports

Local Craft Connector

 

Remote Connector

 

 

 

 

Signal

 

Pin

Signal

Pin

 

 

 

 

 

Local CD

 

1

CD

1

 

 

 

 

 

Local RD (Received Data)

 

2

RD

3

 

 

 

 

 

Local TD (Transmitted Data)

 

3

TD

2

 

 

 

 

 

Local DTR (Data Terminal Ready)

 

4

DTR

6

 

 

 

 

 

Ground

 

5

GND

5

 

 

 

 

 

Local DSR (Data Set Ready)

 

6

DCE

4

 

 

 

 

 

Local RTS (Request to Send)

 

7

RTS

8

 

 

 

 

 

Local CTS (Clear to Send)

 

8

CTS

7

 

 

 

 

 

Local RI (Ring Indicator)

 

9

RI

9

 

 

 

 

 

The default settings for the Remote serial port are DTE, 9600 Baud, 8 bits, 1 stop bit, no parity (also known as 8-1-N), echo on, and handshaking disabled. The local port settings revert to factory default values when you reset the IMC.

097-58001-02 Revision G – April 2008

TimeProvider User’s Guide 79