Chapter 6 Maintaining and Troubleshooting the TimeProvider

Troubleshooting the TimeProvider

Table 6-5. Event Codes (Continued)

Event ID

Keyword

AID

Default Value/

Description of Values

Description

TYPE

Keyword

 

 

 

 

 

 

 

RESET

The indicated IOC is

EQPT

n/a

n/a

 

being restarted after a

 

 

 

 

user-requested reset.

 

 

 

 

All alarms are cleared,

 

 

 

 

if it was Active, it

 

 

 

 

becomes Standby

 

 

 

 

 

 

 

 

SYSMODE

The system mode of

EQPT

SSU

SSU – Sync Supply Unit

 

operation has been

 

 

mode

 

changed

 

 

SUB – Subtending mode

 

 

 

 

PRR – Primary Reference

 

 

 

 

Receiver mode

 

 

 

 

 

 

 

IOC Clock Events

 

 

 

 

 

 

CLKFSTLK

The local oscillator in

EQPT

n/a

n/a

 

the specified IOC is in

 

 

 

 

Fast-Lock mode

 

 

 

 

 

 

 

 

CLKLOCK

The local oscillator in

EQPT

n/a

n/a

 

the specified IOC is in

 

 

 

 

Lock mode

 

 

 

 

 

 

 

 

SCAVAIL

The specified IOC is in

EQPT

OFF

OFF – SmartClock is not

 

SmartClock mode

 

 

available

 

 

 

 

ON – SmartClock is available

 

 

 

 

 

 

 

IOC Input Events

 

 

 

 

 

 

CRCENA

Indicates whether the

T1

DISABLE

ENABLE DISABLE

 

E1 (CAS/CCS) inputs

 

 

 

 

are using CRC4

 

 

 

 

checking. If the E1

 

 

 

 

input is provisioned to

 

 

 

 

read SSMs, then this

 

 

 

 

value is Enabled

 

 

 

 

 

 

 

 

097-58001-02 Revision G – April 2008

TimeProvider User’s Guide 171

Page 171
Image 171
Symmetricom 1000, 1100 manual IOC Clock Events, IOC Input Events