Chapter 6 Maintaining and Troubleshooting the TimeProvider

Diagnosing the IMC

Table 6-3. LED Conditions for the IMC and IMC/TPIU (Continued)

LED Name

Condition

Description

 

 

 

Major

Red

Major system alarm

 

Off

No alarm

 

 

 

Minor

Yellow

Minor system alarm

 

Off

No alarm

 

 

 

Alarm Cutoff (ACO)

Green

On

 

Off

Off

 

 

 

Antenna Power

Green

Internal TPIU is communicating with Antenna

(IMC/TPIU only)

Red

Internal TPIU has lost communication with Antenna

 

Off

GPS is disabled

 

 

 

Antenna Signal

Green

Antenna is communicating with the internal TPIU

(IMC/TPIU only)

Red

Master shelf is powering up

 

Off

Antenna has lost communication with the internal TPIU

 

 

 

Interpreting Error Messages

Error messages appear on the console as they occur, and include the time and date of occurrence. Refer to the event codes described in Table 6-5and to the alarm codes described in Table 6-7.

Replacing the IMC or IMC/TPIU

You can remove the IMC or the IMC/TPIU from the shelf and replace it without affecting outputs.

1.Save the contents of the IMC memory in an IOC by issuing the following command:

CPY-MEM:::::IMC,IOC,IMC;

This command may take more than two seconds to execute; if it does, then the In-Process response is issued. See the TimeProvider TL1 Reference Guide for more information on the CPY-MEM command.

2.Attach a wrist grounding strap and connect it to the TimeProvider chassis.

3.Remove the IMC by loosening the captive screws and pulling the IMC from the shelf using the U-shaped handles.

Warning: To avoid possible electrostatic damage to the IMC, place it in a static-free bag or on a static-free surface.

097-58001-02 Revision G – April 2008

TimeProvider User’s Guide 163

Page 163
Image 163