Symmetricom 1000, 1100 manual Setting Communications Parameters, Setting RS-232 Parameters

Models: 1100 1000

1 224
Download 224 pages 12.25 Kb
Page 91
Image 91

Chapter 4 Provisioning the TimeProvider

Setting Communications Parameters

Setting Ethernet Parameters

Set up the Ethernet port, if you are using it, by following the procedure in Setting Ethernet Parameters, on page 93.

Setting User Security

Set up the user security (usernames and passwords), if you are using it, by following the procedure in Defining the Security Parameters, on page 94.

Setting Communications Parameters

If you want to change the communications parameter values, use the ED-EQPT command. The following sections describe the commands for performing each individual task. For detailed information on the ED-EQPT command, see the TimeProvider TL1 Reference Guide. Record the values you provision in Table 4-4.

Setting RS-232 Parameters

This section describes how to set the baud rate, the handshaking mode, and echo modes on the local and remote ports. The default values are 9600 baud, No flow control, echo mode disabled, tidquiet disabled.

Setting the Baud Rate

Use the ED-EQPT command to provision the baud rate on the Local or Remote port.

ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;

This command has a default access level of ADMIN.

<aid>

<keyword>

<value>

Description

Default value

 

 

 

 

 

COMp

BAUD

2400 9600 19200

Baud rate

9600

p = L R

 

28800 38400 57600

 

 

 

 

115200

 

 

 

 

 

 

 

Sample Command

ED-EQPT::COML:TS1000::BAUD=9600;

This command sets the local Craft communications port to 9600 baud.

Normal Response

TIMEPROVIDER 03-10-24 10:10:25

MTS1000 COMPLD

;

097-58001-02 Revision G – April 2008

TimeProvider User’s Guide 91

Page 91
Image 91
Symmetricom 1000, 1100 manual Setting Communications Parameters, Setting RS-232 Parameters, Setting Ethernet Parameters