Chapter 4 Provisioning the TimeProvider

Provisioning Alarms

This command has a default access level of USER.

<aid>

Description

 

 

ALL (or null)

Access identifiers

SYS

 

IMC

 

IOCm (m = 1 2)

 

PRS

 

INPp (p = 1 2)

 

OUTg (g = A B C D)

 

 

 

Normal Response Format

<cr><lf><lf>

^^^sid^date^time<cr><lf>

M^<ctag>^COMPLD

^^^”<aid>,aidtype:ntfcncde,condtype,srveff,ocrdat,ocrtim

<:condscr>”<cr><lf>*

;

where * indicates zero or more of the preceding element

Value

Description

 

 

<aid>

Access identifier

 

 

aidtype

Access identifier type

 

EQPT – alarm associated with operation of the system

 

T1 – alarm associated with inputs or outputs

 

 

ntfcncde

Notification code:

 

MN – Minor alarm

 

MJ – Major alarm

 

CR – Critical alarm

 

 

condtype

Condition type – keyword associated with the command

 

 

srveff

Service affecting indicator

 

 

ocrdat

Occurrence date of the alarm

 

 

ocrtim

Occurrence time of the alarm

 

 

condscr

Optional condition description – text string enclosed in quotation

 

marks

 

 

Sample Command

RTRV-ALM:::TS1000;

This command causes the TimeProvider to return all current alarms.

097-58001-02 Revision G – April 2008

TimeProvider User’s Guide 133

Page 133
Image 133
Symmetricom 1000, 1100 manual Aid Description, Sys Imc, Value Description