Chapter 4 Provisioning the TimeProvider

 

 

 

 

 

Provisioning Alarms

Table 4-3. Alarm Conditions and Defaults

 

 

 

 

 

 

 

 

 

 

 

 

 

Description of Alarm

Possible

Error

Error

Default Level

 

 

 

Alarm ID

Alarm

Delay

Delay

 

 

Condition

SSU

SUB

 

Levels

Default

Editable?

 

 

Mode

Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<aid> = SYS

 

 

 

 

 

 

 

 

 

 

PWRA

Loss of A power

MN MJ

IMMED

No

MJ

MJ

 

 

CR

 

 

 

 

 

 

 

 

 

 

 

PWRB

Loss of B power

MN MJ

IMMED

No

MJ

MJ

 

 

CR

 

 

 

 

 

 

 

 

 

 

 

EXPFAIL

Connection to the

NR NA

IMMED

No

MJ

MJ

 

Expansion Panel is lost

MN MJ

 

 

 

 

 

 

CR

 

 

 

 

 

 

 

 

 

 

 

EXTALM

External alarm

NR NA

IMMED

No

MN

MN

 

generated by external

MN MJ

 

 

 

 

 

equipment

CR

 

 

 

 

 

 

 

 

 

 

 

 

 

<aid> = IMC

 

 

 

 

 

 

 

 

 

 

IOC1COMM

Comm alarm with IOC

NR NA

IMMED

No

MN

MN

 

1

MN MJ

 

 

 

 

 

 

CR

 

 

 

 

 

 

 

 

 

 

 

IOC2COMM

Comm alarm with IOC

NR NA

IMMED

No

MN

MN

 

2

MN MJ

 

 

 

 

 

 

CR

 

 

 

 

 

 

 

 

 

 

 

 

 

<aid> = IOC

 

 

 

 

 

 

 

 

 

 

IOC1COMM

Comm alarm from IMC

NR NA

IMMED

No

MN

MN

 

module to IOC1 module

MN MJ

 

 

 

 

 

 

CR

 

 

 

 

 

 

 

 

 

 

 

IOC2COMM

Comm alarm from IMC

NR NA

IMMED

No

MN

MN

 

module to IOC2 module

MN MJ

 

 

 

 

 

 

CR

 

 

 

 

 

 

 

 

 

 

 

IOC1TO2

Comm alarm from

NR NA

IMMED

No

MN

MN

COMM

IOC1 to IOC2

MN MJ

 

 

 

 

 

 

CR

 

 

 

 

 

 

 

 

 

 

 

IOC2TO1

Comm alarm from

NR NA

IMMED

No

MN

MN

COMM

IOC2 to IOC1

MN MJ

 

 

 

 

 

 

CR

 

 

 

 

 

 

 

 

 

 

 

IOCFAIL

Summary alarm of IOC

MN MJ

IMMED

No

MJ

MJ

 

failures; for example,

CR

 

 

 

 

 

calibration was unsuc-

 

 

 

 

 

 

cessful

 

 

 

 

 

 

 

 

 

 

 

 

097-58001-02 Revision G – April 2008

TimeProvider User’s Guide 127

Page 127
Image 127
Symmetricom 1000, 1100 manual Levels Default Editable? Mode Aid = SYS, Aid = IMC, Aid = IOC