Symmetricom 1100, 1000 manual Diagnosing the IMC, Reading LED Conditions

Models: 1100 1000

1 224
Download 224 pages 12.25 Kb
Page 162
Image 162

Chapter 6 Maintaining and Troubleshooting the TimeProvider

Diagnosing the IMC

4.Retrieve the contents of the IOC memory stored in the IMC by issuing the following command.

CPY-MEM:::::IMC,IOC,IOC;

This command may take more than two seconds to execute; if it does, then the In-Process response is issued. See the TimeProvider TL1 Reference Guide for more information on the CPY-MEM command.

If you have not stored the contents of the IOC memory in the IMC, then provision the IOC using the procedures and commands described in Chapter 4, Provisioning the TimeProvider.

5. Issue the following TL1 command to place the IOC in service:

ED-EQPT::IOC1:::IOCSTATE=INSRV;

6.Install the IOC into the right slot of the shelf and tighten the captive retaining screws. This IOC will become the Standby IOC.

7.Wait for the IOC to reboot and qualify the reference inputs. During this time the Active IOC updates the new IOC’s memory with current values.

8.Issue the following TL1 command to place the Standby IOC in service:

ED-EQPT::IOC2:::IOCSTATE=INSRV;

Diagnosing the IMC

Reading LED Conditions

Table 6-3shows the function of the LED indicators on the front panel of the IMC and IMC/TPIU.

Table 6-3. LED Conditions for the IMC and IMC/TPIU

LED Name

Condition

Description

 

 

 

Power

Green

Power is On

 

Off

Power is Off

 

 

 

Fail

Red

Card failure

 

Off

No failure

 

 

 

Alarm

Red

Card alarm

 

Off

No alarm

 

 

 

Critical

Red

Critical system alarm

 

Off

No alarm

 

 

 

 

 

 

162 TimeProvider User’s Guide

097-58001-02 Revision G – April 2008

Page 162
Image 162