2MENU-SPECIFIC SETTINGS

9. ALARM REC MODE SET

Set the recording conditions for alarm recording as follows.

Setting alarm recording

In order to carry out alarm recording, it will be necessary to set operation patterns and recording conditions.

1

1 Select a mode using “ALARM RECORDING” from the pull-down menu on the screen.

[Settings] (‹ indicates default setting.)

Setting

Description

‹OFF

Does not perform alarm recording.

 

 

ENABLED

Alarm recording is always performed,

regardless of timer recording or timer settings.

 

 

 

AL-REC ON

Alarm recording is performed only during timer

TIMER

recording.

 

 

AL-REC OFF

Alarm recording is performed only during

TIMER

recording other than timer recording.

 

 

OLY AL-RC

Alarm recording is performed only in the

period set for timer recording without timer

ON TMR

recording actually being performed.

 

 

 

Setting the alarm interleave

4 Select “ALARM INTERLEAVE” from the pull-down menu on the screen.

Setting the picture quality for recording

Set the picture quality for alarm recording as follows.

2

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

6

NETWORK SETTINGS

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 Select “PICTURE QUALITY” from the pull-down menu on the screen.

[Settings] (‹ indicates default setting.)

Setting

Description

SUPER FINE

Super Fine

 

 

FINE

Fine

‹ENHANCED Enhanced

NORMAL Normal

BASIC Basic

Setting audio recording

Audio can be recorded together with images when performing alarm recording. Note, however, that since this audio data will also be stored in the alarm recording area, the recording time for this area will be reduced.

3 Select “AUDIO RECORDING” from the pull-down menu on the screen.

[Settings] (‹ indicates default setting.)

 

Setting

Description

 

ON

Audio will be recorded.

 

 

 

 

 

‹OFF

Audio will not be recorded.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

zAudio recording can only be specified when the recording rate is between A30 and A1 FPS.

[Settings] (‹ indicates default setting.)

Setting

Description

SW

Recording is switched between camera video

including an alarm and video from all connected

 

cameras.

 

 

18

English

Page 19
Image 19
Sanyo DSR-3506P manual MENU-SPECIFIC Settings Alarm REC Mode SET, Setting alarm recording, Setting the alarm interleave