SATO CL612VA, CL608VA manual Start/Stop Label

Models: CL612VA CL608VA

1 256
Download 256 pages 52.84 Kb
Page 144
Image 144

Section 4. Programming Reference

Start/Stop Label

Command Structure

Start Command:

<ESC>A

 

Stop Command:

<ESC>Z

 

Example:

See above

 

Placement:

<ESC>A must precede data

 

 

<ESC>Z must follow data

 

Default:

None

Command Function

For all print jobs, the Start command must precede the data, and the

 

Stop command must follow. The print job will not run properly if these

 

are not in place.

 

Input to Printer

<ESC>A

 

 

 

<ESC>H0001<ESC>V0100<ESC>WB1SATO

 

<ESC>H0130<ESC>V0200<ESC>B103150*CL408*

 

<ESC>H0170<ESC>V0360<ESC>L0202<ESC>S*CL408*

 

<ESC>Q1<ESC>Z

 

Printer Output

There is not output for these commands they are not accompanied by

 

other label printing commands. However, these commands must

 

precede and follow each print job sent to the printer.

Page 4-74

9001035 Rev. E

SATO CL Series Printers