Section 2. Installation and Configuration

PRINTER DIP SWITCH CONFIGURATION

ALL MODELS

 

 

DIP Switch Panels

There are three DIP switches (DSW1, DSW2 and DSW3). On the CL608 and the CL612, DSW2 and DSW3 are located underneath a flip-down cover of the front panel. DSW1 (used to set the RS232 parameters) is located on the Serial Interface board and the board must be removed to change the settings. DSW2 and DSW3 are located behind the Front Access Door on the CL408 and CL412. These switches can be used to set:

RS232C transmit/receive parameters

Thermal transfer or direct thermal mode

Label sensor enable/disable

Head check mode

Hex dump mode

Receive buffer size

Operation mode

Each switch is an eight section “toggle” switch. The ON position is always to the top. To set the switches, first power the unit Off, then position the DIP switches. Finally, after placing the switches in the desired positions, power the printer back on. The switch settings are read by the printer electronics during the power up sequence. They will not become effective until the power is cycled.

RS232 Transmit/Receive Setting

Data Bit Selection (DSW1-1). This switch sets the printer to receive either 7 or 8

DSW1-1

SETTING

 

 

Off

8 data bits

 

 

On

7 data bits

DSW1

ON

OFF

1 2 3 4 5 6 7 8

bit data bits for each byte transmitted. Located on RS232 Interface Card.

DSW1-2

DSW1-3

SETTING

 

 

 

 

DSW1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

Off

No Parity

ON

 

 

 

 

 

 

 

 

 

 

Off

On

Even

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On

Off

Odd

 

 

 

 

 

 

 

 

 

 

1

2

3

4

 

5

6

7

8

 

 

 

 

On

On

Not Used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parity Selection (DSW1-2,DSW1-3).These switches select the type of parity used for error detection.