Section 4. Programming Reference

Character, Fixed Spacing

Command Structure

<ESC>PR

 

 

Example:

See Above

 

Placement:

Preceding the data

 

Default:

The default is Proportional Spacing.

Command Function

To reset proportional spacing and place the printer back to fixed

 

spacing

 

Printer Input

<ESC>A

 

 

<ESC>H0025<ESC>V0050<ESC>PS

 

<ESC>L0202<ESC>XMPROPORTIONAL SPACING

<ESC>H0025<ESC>V0130<ESC>PR <ESC>L0202<ESC>XMFIXED SPACING <ESC>Q1<ESC>Z

Printer Output

Special Notes

1. This command only works with the proportionally spaced fonts XU,

 

XM, XS, XL and XB.