SATO CL612VA, CL608VA manual Calendar Set, Command Structure ESCWTaabbccddee, ESCWT9101311200

Models: CL612VA CL608VA

1 256
Download 256 pages 52.84 Kb
Page 150
Image 150

Section 4. Programming Reference

Calendar Set

Command Structure <ESC>WTaabbccddee

aa

=

Year (01-99)

bb

=

Month (01-12)

cc

=

Day (01-31)

dd

=

Hour (00-23)

ee

=

Minute (00-59)

 

Example:

<ESC>WT9101311200

 

Placement:

This command must be sent in an independent data

 

 

stream.

 

Default:

None

Command Function

To set the time and date of the printer’s internal clock.

Input to Printer

<ESC>A

 

 

<ESC>WT9312251300

 

<ESC>Z

 

Printer Output

There is no printer output for this command. It sets the current date to

 

December 25,

1993 and the current time to 1:00 PM in the printer.

Special Notes

This command requires the Calendar Option. See your SATO

 

representative for details.