Section 2. Installation and Configuration

POTENTIOMETER ADJUSTMENTS

CL608 and CL612

 

 

DISPLAY

This potentiometer is used to adjust the contrast of the LCD display for optimum viewing under various lighting conditions.

POTENTIOMETER ADJUSTMENTS

CL408 and CL412

 

 

SENSOR THRESHOLD

This potentiometer is operational only if the Label Dispense Option is installed. It is used to set the Label Taken Sensor threshold. For information on making this adjustment, see Appendix D: Accessories.

HEX DUMP DIAGNOSTIC LABELS

ALL MODELS

 

 

In addition to the User Test Print Labels (see page 2-37), the printer contents of the receive and print buffers can be examined using the Hex Dump Test Labels.

Print Buffer Hex Dump

The contents of the Print Buffer can be examined using the Hex Dump mode. The label numbers each line of data received in the left-hand column, the data in hexadecimal format in the center columns followed by the same data in ASCII format in the right-hand column.

1.Turn the printer on.

2.Send and print label.

3.Place the printer in the Off Line mode by pressing the LINE key. The LINE LED should go out.

4.Place DSW2-4in the On position.

5.Press the LINE key to place the printer back in the On Line status.

6.Press the FEED key.

7.A label should be printed containing the contents of the print buffer in Hexadecimal format.

8.Return DSW2-4to the Off position.

9.Turn the printer off and then back on to place it back in the normal print mode.

Receive Buffer Hex Dump

The data that is being received by the printer (before it is placed in the Print Buffer) can be examined by using the Hex Dump Mode. The label numbers each line of

SATO CL Series Printers

9001035 Rev. E

Page 2-41

Page 59