Section 2. Installation and Configuration

Back-Feed Selection (DSW3-4). When Back-Feed is enabled, the printer will position the label for dispensing/cutting and retract it before printing the next label. See page 2-19 for information on setting the amount of offset.

DSW3

DSW3-4

SETTING

 

 

Off

Disabled

 

 

On

Enabled

ON

OFF

1 2 3 4 5 6 7 8

External Signal Interface. See Section 5: Interface Specifications for information on the External Signals.

EXT Print Start Signal Selection (DSW3-5). Allows an external device to initiate a label print. See page 5-10 for a description of signal requirements.

Note: This switch must be in the On position if a VeriScan is used to control the printer via the EXT connector.

DSW3-5

SETTING

 

 

Off

Disabled

 

 

On

Enabled

 

 

DSW3

ON

OFF

1 2 3 4 5 6 7 8

External Signal Type Selection (DSW3-6, DSW3-7). Selects the type of

output signal. See page 5-11 for a definition of signal types.

DSW3-6

DSW3-7

SETTING

 

 

 

 

DSW3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

Off

Type 4

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

On

Type 3

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On

Off

Type 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

 

5

6

7

8

 

 

 

 

On

On

Type 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Repeat Print via External Signal (DSW3-8). Allows an external device to control the reprint of the label in the print buffer. See page 5-10 for a description of the signal requirements.

DSW3-8

SETTING

 

 

Off

Disabled

 

 

On

Enabled

DSW3

ON

OFF

1 2 3 4 5 6 7 8

Reserved for Future Use (DSW2-6)

Note: The Centronics (Parallel) communications port on the CL608 and CL612 is always enabled regardless of the settings for the RS232 port. There are no settings for Centronics! Both the Centronics and RS232 ports are active at all times. Care should be taken to ensure that data is not transmitted to both ports simultaneously as the received message will be corrupted.