SATO CL608VA Memory Card Function Format/Field Recall, Command Structure ESCYR,aa ESC/D,bb,cc...c

Models: CL612VA CL608VA

1 256
Download 256 pages 52.84 Kb
Page 157
Image 157

Section 4. Programming Reference

Memory Card Function

Format/Field Recall

Command Structure <ESC>YR,aa <ESC>/D,bb,cc...c

 

aa

=

Format number to be recalled (01-99)

 

bb

=

Field number to be recalled (01-99)

 

cc...c =

Data to be placed in recalled field.

 

Example:

<ESC>YR,01<ESC>/D,01,99

 

Placement: Immediately after <ESC>CC Slot Select command

 

Default:

None

Command Function

To recall a field from a stored format and place new data in the field.

Printer Input

<ESC>A

 

 

<ESC>CC1

 

 

<ESC>YR,02<ESC>/D,01,TWO FIELDS OF<ESC>/D,02,VARIABLE DATA

 

<ESC>Q1<ESC>Z

Printer Output

Special Notes

1.

This command requires the Memory Card option. See your SATO

 

 

representative for details.

 

2.

Only one format can be recalled at a time. However, multiple fields

 

 

may be recalled from the same format.

 

3.

The number of data characters contained in the “cc...c” field cannot

 

 

exceed the value designated in the <ESC>/N Field Store

 

 

command. If it does, the data will be truncated to fit the field

 

 

length defined in the Field Store Command.

SATO CL Series Printers

9001035 Rev. E

Page 4-87

Page 157
Image 157
SATO CL608VA Memory Card Function Format/Field Recall, Command Structure ESCYR,aa ESC/D,bb,cc...c, ESCYR,01 ESC/D,01,99