SATO LM408/412E manual Dipswitch Settings, Switch, Led Indicator Status, Description

Models: LM408/412E

1 98
Download 98 pages 19.33 Kb
Page 28
Image 28
SWITCH

Unit 3: Installation

DIPSWITCH SETTINGS

The dipswitches serve to initialize the configuration saved on the Wireless-LAN board, print the configuration, and make a self- diagnosis. To communicate with the host,set the communication mode by through switches 5 and 6, then set the remaining switches to the OFF position.

Print of configuration and self-diagnsis are operable only on the screen after turning on the printer. Ensure all switches are in the OFF position when operating the printer.

SWITCH

SETTING

 

 

1Reserved for test use only (setup prohibited).

2LAN board EEPROM initialization (initialize configuration).

3Print configuration details on a label (diagnostic & configuration).

4Print a self-diagmosis of the board onto a label (wireless mode).

NOTE: The communication mode may be set within the printer’s Interface Mode. Go to [Communication] of the Interface Mode to enable setup by either the dipswitches or through the Interface Mode.

LED INDICATOR STATUS

INDICATOR 1

INDICATOR 2

INDICATOR 3

DESCRIPTION

 

 

 

 

ON

OFF

OFF

Weak Signal (1-50%)

 

 

 

 

ON

ON

OFF

Moderate Signal (50-75%)

 

 

 

 

ON

ON

ON

Strong Signal (75-100%)

 

 

 

 

OFF

OFF

ON

802.11 Ad hoc

 

 

 

 

OFF

ON

OFF

Ad hoc

 

 

 

 

 

SOFTWARE SPECIFICATIONS

 

 

Corresponding Protocol

TCP/IP

 

 

Network Layer

ARP, RARP, IP, ICMP

 

 

Session Layer

TCP, UDP

 

 

Application Layer

LPD, FTP, TELNET, BOOTP, DHCP

 

 

NOTE: Print data can be sent by LPR and FTP of TCP/IP and dedicated socket protocol. Printer status is obtainable by dedicated socket protocol.

NOTE: In the TCP/IP protocol enviroment, LPD and FTP are provided for printing; TELNET for variable setup; ARP, RARP, and BOOTP/DHCP for address setup.

LPD protocol complies with RFC1179 and handles the list of logical printer name as queue name such as lp, sjis, euc. In addition, a banner page can be printed by a proper setup.

When sending the job by LPR, the transmission order of data file/control file within the job will not affect print operation. In addition, if the banner page is specified, it will be added to each data file. Job deletion by LPR is not available.

FTP protocol complies with RFC959 and handles the list of logical printer name as a transfer directory. File transfer to this directory executes print operation. It is possible to specify ASCII(A), Binary(I) and TENEX(L8) as transfer mode - although the mode difference is dependent on the client. A banner page may be printed with a proper setup.

TELNET Complies with RFC854. This operation consists of interactive menu form and enables change and reference of internal setup, and to display status. To change the setup, enter “root” user and password at the time of login. Default of root pasword is set as null (linefeed only).

LM408-412e Operator Manual

3-13

PN: 9001155A

Page 28
Image 28
SATO LM408/412E manual Dipswitch Settings, Switch, Led Indicator Status, Description, Software Specifications