![TEST PRINT MODE](/images/new-backgrounds/110886/110886103x1.webp)
Section 3. Configuration
TEST PRINT MODE
CONFIGURATION
This option allows you to print a test label. It is recommended that you print a test label after you have changed any of the settings in the Advanced Mode. The test label allows you to verify that you indeed did make the desired changes. To enter the Test Print Mode, power the printer on while pressing the FEED key. The printer will beep. Release the FEED key and the printer will display the following message on the LCD panel:
1.Use the LINE key to step the cursor to type of test label you wish to print. The choices are:
CONFIGURATION BARCODE HEADCHECK MEMORY FACTORY
TEST PRINT SIZE
10 CM
PRESS FEED KEY TO STOP PRINTING
Note: This screen will not be displayed for the Memory Test Label.
Once you have selected the type of test label to be printed, use the FEED key to accept the selection and the display advances to the Test Print Size display. This display allows you to select the label width.
1.Use the LINE key to select the lable width. Each time the LINE key is pressed, the label size advances 1 cm until it reaches a maximum width of 26 cm, at which point it will wrap to the smallest size of 13 cm.
2.Pressing the FEED key accepts the selection and starts printing test labels continuously.
3.Press the FEED key to stop the printer.
4.To exit the Test Print Mode, power the printer off and then back on.
DEFAULT SETTING MODE
Occassionally it is desirable to reset all printer configuration settings to their original default conditions. This allows the operator to start reconfiguration of the printer starting from a know set of conditions.
V05.00.03.00
INITIALIZING
DEFAULT SETTING
YES NO
Displays the firmware during the initialization.
You enter the Default Setting Mode by pressing the LINE and FEED keys while simultaneously powering the printer on. The printer will emit one long beep after which the FEED and LINE keys should be released.
1.Use LINE key to select either the YES or NO.
2.Once the desired setting is selected, pressing the FEED key will accept the selection and the printer will reset to the original default conditions.
Page | PN 9001105 Rev. A | SATO |