Object 0x605E: Fault reaction option code

CANopen DSP 402 Implementation Guide

MAN-CAN402IG (Ver. 1.2)

35

Object 0x605E: Fault reaction option code

Object description:

 

Index

 

605Eh

 

Name

 

Fault reaction option code

 

Object code

 

VAR

 

Data type

 

INTEGER16

 

Category

 

Optional

Entry description:

 

 

 

 

 

 

 

Access

 

Read/write

 

PDO mapping

 

No

 

Value range

 

INTEGER16

 

Default value

 

0

Data description:

 

 

Value

Description

-32,768…-1

Manufacturer specific

0

Disable drive function

1…4

Not supported

1…32,767

Reserved

Notes:

An attempt to set an unsupported value causes the transmission of abort code 0609 0030: Value exceeded.

All drive faults are considered fatal. When a fatal fault occurs, the drive is no longer able to control the motor, requiring that the drive be switched-off immediately.