Event: Enable Operation command received from host.

CANopen DSP 402 Implementation Guide

MAN-CAN402IG (Ver. 1.2)

24

State Transition 4: SWITCHED ON => OPERATION ENABLE

Event: Enable Operation command received from host.

Action: The drive function is enabled.

State Transition 5: OPERATION ENABLE => SWITCHED ON

Event: Disable Operation command received from host.

Action: The drive operation is disabled.

State Transition 6: SWITCHED ON => READY TO SWITCH ON

Event: Shutdown command received from host.

Action: The power section is switched off.

State Transition 7: READY TO SWITCH ON => SWITCH ON DISABLED

Event: Quick Stop and Disable Voltage commands received from host.

Action: None.

State Transition 8: OPERATION ENABLE => READY TO SWITCH ON

Event: Shutdown command received from host.

Action: The power section is switched off immediately, and the motor is free to rotate if not braked.

State Transition 9: OPERATION ENABLE => SWITCH ON DISABLED

Event: Disable Voltage command received from host.

Action: The power section is switched off immediately, and the motor is free to rotate if not braked.

State Transition 10: SWITCHED ON =>SWITCH ON DISABLED

Event: Disable Voltage or Quick Stop command received from host.

Action: The power section is switched off immediately, and the motor is free to rotate if not braked.

State Transition 11: OPERATION ENABLE =>QUICK STOP ACTIVE

Event: Quick Stop command received from host.

Action: The quick stop function is executed.

State Transition 12: QUICK STOP ACTIVE=>SWITCH ON DISABLED

Event: Quick Stop completed or Disable Voltage command received from host. This transition is possible if the quick stop option code is higher than 5 (stay in QUICK STOP ACTIVE state).

Action: The profile generator finished the deceleration and the motor is disabled.

State Transition 13: All => FAULT REACTION ACTIVE

Event: A fault has occurred in the drive.

Action: Execute appropriate fault reaction.

State Transition 14: FAULT REACTION ACTIVE => FAULT

Event: The fault reaction is completed.

Action: The drive function is disabled. The power section may be switched off.

State Transition 15: FAULT=>SWITCH ON DISABLED

Event: Fault Reset command received from host.

Action: The fault condition is reset if no fault currently exists in the drive.

Page 30
Image 30
Elmo DSP 402 manual Event Enable Operation command received from host, Action None