Object 0x605D: Halt option code

CANopen DSP 402 Implementation Guide

MAN-CAN402IG (Ver. 1.2)

34

Object 0x605D: Halt option code

This parameter determines which action should be taken if bit 8 (halt) in the controlword is active.

Object description:

 

Index

 

605Dh

 

Name

 

Halt option code

 

Object code

 

VAR

 

Data type

 

INTEGER16

 

Category

 

Optional

Entry description:

 

 

 

 

 

 

 

Access

 

Read/write

 

PDO mapping

 

No

 

Value range

 

INTEGER16

 

Default value

 

1

Data description:

 

 

Value

Description

-32,768…-1

Manufacturer specific

0

Disable drive function

1

Slow down on slow-down ramp

2

Slow down on quick-stop ramp

3

Slow down on current limit (only for tq mode)

3…32,767

Reserved

In Profile Position mode, the Halt option is not affected when this object is set.