Elmo DSP 402 manual 9.3Functional Description, Object 0x609A Homing acceleration, Index, 609Ah

Models: DSP 402

1 116
Download 116 pages 36.42 Kb
Page 64
Image 64
Object 0x609A: Homing acceleration

CANopen DSP 402 Implementation Guide

MAN-CAN402IG (Ver. 1.2)

58

The speed is submitted to the maximum speed limit given by the user during setup. Otherwise, an abort message with abort code 0609 0030, “Value range of parameter exceeded” is activated. If the limits have been changed during the process, the drive enters a fault state.

Object 0x609A: Homing acceleration

This object establishes the acceleration to be used for all accelerations and decelerations with the standard homing modes, and is given in acceleration units.

Object description:

 

Index

 

609Ah

 

Name

 

Homing acceleration

 

Object code

 

VAR

 

Data type

 

UNSIGNED32

 

Category

 

Optional

Entry description:

 

 

 

 

 

 

 

Access

 

Read/write

 

PDO mapping

 

No

 

Value range

 

UNSIGNED32

 

Default value

 

No

Home deceleration is performed according to the SD value set during setup. The user may use the binary interpreter to modify this value. Refer to the relevant Command Reference Manual for the SD parameter information.

9.3Functional Description

Choosing a method of homing by writing a value to homing method clearly establishes the: Homing signal (positive limit switch, negative limit switch, home switch)

Direction of actuation

Position of the index pulse, where appropriate

Homing is performed on either the main position sensor (PX) or the auxiliary position sensor (PY), depending on the unit mode — for position loop (UM=5) or dual loop (UM=4) — respectively. The relevant source is selected when homing is activated by the controlword.

The home position and zero position are offset by the home offset (see the home offset definition for how this offset is used).