Elmo DSP 402 manual Value, Description, Object 0x6061 Modes of operation display, Index, 6061h

Models: DSP 402

1 116
Download 116 pages 36.42 Kb
Page 43
Image 43
Object 0x6061: Modes of operation display

CANopen DSP 402 Implementation Guide

MAN-CAN402IG (Ver. 1.2)

37

Data description:

Value

Description

-128…-2

Reserved

-1

No mode

0

Reserved

1

Profile position mode

2

Velocity (not supported)

3

Profiled velocity mode

4

Torque profiled mode

5

Reserved

6

Homing mode

7

Interpolated position mode

8…127

Reserved

Notes:

A read of this object shows only the value of modes of operation. The actual mode of the drive is reflected in the modes of operation display object. It may be changed by writing to modes of operation.

An attempt to access an unsupported mode causes the transmission of abort code 0609 0030: Value exceeded.

Object 0x6061: Modes of operation display

This object shows the current mode of operation. The meaning of the returned value corresponds to that of the modes of operation option code (index 6060h).

Object description:

 

Index

 

6061h

 

Name

 

Modes of operation display

 

Object code

 

VAR

 

Data type

 

INTEGER8

 

Category

 

Mandatory

Entry description:

 

 

 

 

 

 

 

Access

 

Read only

 

PDO mapping

 

No

 

Value range

 

INTEGER8

 

Default value

 

-1

Data description:

Similar to object 6060h, modes of operation.

The actual mode is reflected in the modes of operation display (index 6061h), and not in modes of operation (index 6060h).

Page 43
Image 43
Elmo DSP 402 manual Value, Description, Object 0x6061 Modes of operation display, Index, 6061h