2. Command Codes

Programming Manual

Memory Card Function

Format/Field Recall

Command Structure:

<ESC>YR,aa <ESC>/D,bb,cc...c

aa:Format number to be recalled (01-99)

bb:Field number to be recalled (01-99)

cc...c: Data to be placed in recalled field.

Example: <ESC>YR,01<ESC>/D,01,99

Placement: Immediately after <ESC>CC Slot Select command

Default: None

Function:

To recall a field from a stored format and place new data in the field.

Input:

<ESC>A

<ESC>CC1

<ESC>YR,02<ESC>/D,01,TWO FIELDS OF<ESC>/D,02,VARIABLE

DATA

<ESC>Q1<ESC>Z

Note:

1.This command requires the Memory Card option. See your SATO representative for details.

2.Only one format can be recalled at a time. However, multiple fields may be recalled from the same format.

3.The number of data characters contained in the “cc...c” field can- not exceed the value designated in the <ESC>/N Field Store com- mand. If it does, the data will be truncated to fit the field length defined in the Field Store Command.