2. Command CodesProgramming Manual

Rotate, Moving Base Reference Point

Command Structure:

Normal Direction: <ESC>N

Rotated Direction: <ESC>R

Example: See above

Placement: Preceding any printed data to be rotated

Default: <ESC>N

Function:

The <ESC>R command rotates the printing of all subsequent images in a print job by 90° counterclockwise each time it is used. It also mo- ves the base reference point to a different corner of the print area.

The <ESC>N command returns to the original base reference point and returns printing to the normal orientation.

Input:

<ESC>A

<ESC>N<ESC>H0100<ESC>V0010<ESC>MNORMAL DIRECTION

<ESC>R<ESC>H0100<ESC>V0100<ESC>MONE

<ESC>R<ESC>H0100<ESC>V0100<ESC>MTWO

<ESC>R<ESC>H0100<ESC>V0100<ESC>MTHREE

<ESC>R<ESC>H0100<ESC>V0100<ESC>MFOUR

<ESC>Q1<ESC>Z