CHAPTER 2. ADJUSTMENTS
[1] Adjustments
General
Since the following adjustments and settings are provided for this model, make adjustments and/or setup as necessary.
1. Adjustments
Adjustments of output voltage (FACTORY ONLY)
1.Install the power supply unit in the machine.
2.Set the recording paper and document.
3.When the document is loaded, power is supplied to the output lines. Confirm that outputs are within the limits below.
Output voltage settings
TEL/LIU PWB | POWER SUPPLY PWB |
CNLIUCN2
CNLIUACNPW
CONTROL PWB
2. IC protectors replacement
ICPs (IC Protectors) are installed to protect the motor driver circuit. ICPs protect various ICs and electronic circuits from an overcurrent con- dition.
The location of ICPs are shown below:
CNLIUACNPW
FU100
CONTROL PWB (TOP SIDE)
(1)FU100
3. Settings
(1) Dial mode selector
DIAL mode (Soft Switch No. SWB4 DATA No. 3)
(step 1) Select "OPTION SETTING".
KEY : FUNCTION 4
DISPLAY: OPTION SETTING PRESS OR #
Output | Voltage limits |
|
|
+5V | 4.75V ∼ 5.25V |
|
|
+24V | 23.3V ∼ 24.7V |
Connector |
|
No. | CNPW |
Pin No. |
|
1 | DG |
2 | +5V |
3 | |
4 | MG |
5 | MG |
6 | MG |
7 | +24V |
8 | VTH |
9 | VTH |
10 | VTH |
(step 2) Select "DIAL MODE". |
| Cursor | |
|
|
| When initially registering, |
|
|
| the mode shows 1=TONE. |
KEY: | # # # # # # # | # # | When registering again, the |
mode which was registered | |||
|
|
| formerly is shown. |
DISPLAY: | DIAL MODE | 1=TONE, 2=PULSE | |
(step 3) Select, using "1" or "2". |
|
| |
KEY: | 1 |
|
|
DISPLAY: | TONE SELECTED |
|
|
KEY: | 2 |
|
|
DISPLAY: | PULSE SELECTED |
|
|
(step 4) End, using the "STOP" key. |
|
| |
KEY: | STOP |
|
|
4.Method of release of starting lock up by Battery Reset
(1) Summary
There is a possibility of release of the lock up by reset the signal BATRST of CPU (FC100), if it lock up when you turn on the power of the set in
(2) Contents
When you turn on the power of the set without EPROM by your mistake, if you turn off the power after, turn on the power with EPROM again, the set don’t start.
In this case, before you judge the cpu (FC100) is wrong, you need to confirm the release of the lock up by reset the signal BATRST. and unknown origin in the same way.
Method of the reset of signal BATRST
Short the between leads of the capacitor C5 on the control PWB,
2 – 1