SW | DATA | ITEM |
|
| Switch setting and function | Initial | Remarks | ||||
NO. | NO. |
| 1 |
|
|
|
| 0 | setting | ||
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| 1 | Auto gain control (MODEM) | Enable |
|
|
|
|
| Disable | 1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2 | End Buzzer | Yes |
|
|
|
|
| No | 1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 3 | Disconnect the line when DIS is received in | No |
|
|
|
|
| Yes | 1 |
|
SW |
| RX mode |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
l | 4 | Equalizer freeze control (MODEM) | On |
|
|
|
|
| Off | 0 |
|
A6 | 5 | Equalizer freeze control 7200 BPS only | No |
|
|
|
|
| Yes | 0 |
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| 6 | CNG transmission in manual TX mode | Yes |
|
|
|
|
| No | 1 |
|
| 7 | Initial compression scheme for sharp fax in | MR mode |
|
|
|
|
| H2 mode | 0 |
|
|
| TX mode |
|
|
|
|
|
|
|
|
|
| 8 | Reserved |
|
|
|
|
|
|
| 0 |
|
|
|
|
|
|
|
|
|
| |||
| 1 | Recall interval |
| Binary input |
|
| 0 | OPTION | |||
| 2 |
| No. = | 8 | 4 | 2 | 1 |
|
| 1 |
|
SW | 3 |
|
| 1 | 2 | 3 | 4 |
|
| 0 |
|
4 |
|
| 0 | 1 | 0 | 1 (5 x 60 sec = 5 min) | 1 |
| |||
l |
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
| |
5 | Recall times |
| Binary input |
|
| 0 | OPTION | ||||
B1 |
|
|
| ||||||||
| 6 |
| No. = | 8 | 4 | 2 | 1 |
|
| 0 |
|
| 7 |
|
| 5 | 6 | 7 | 8 |
|
| 1 |
|
| 8 |
|
| 0 | 0 | 1 | 0 (Twice) | 0 |
| ||
| 1 | Dial pausing (sec/pause) | 4 sec |
|
|
|
|
| 2 sec | 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2 | Reserved |
|
|
|
|
|
|
| 0 |
|
| 3 | Reserved |
|
|
|
|
|
|
| 0 |
|
SW |
|
|
|
|
|
|
|
|
|
|
|
4 | Busy tone detection (after auto dial) | No |
|
|
|
|
| Yes | 1 |
| |
l | 5 | Waiting time after dialing | 90 sec |
|
|
|
|
| 45 sec | 0 |
|
B2 |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
| |
6 | Reserved |
|
|
|
|
|
|
| 0 |
| |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| 7 | Reserved |
|
|
|
|
|
|
| 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 8 | Reserved |
|
|
|
|
|
|
| 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 | Reserved |
|
|
|
|
|
|
| 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2 | Reserved |
|
|
|
|
|
|
| 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 3 | Reserved |
|
|
|
|
|
|
| 0 |
|
SW |
|
|
|
|
|
|
|
|
|
|
|
4 | Reserved |
|
|
|
|
|
|
| 0 |
| |
l |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| |
5 | Reserved |
|
|
|
|
|
|
| 0 |
| |
B3 |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| |
| 6 | Reserved |
|
|
|
|
|
|
| 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 7 | Reserved |
|
|
|
|
|
|
| 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 8 | Hold function | Enable |
|
|
|
|
| Disable | 1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 | Auto Dial Mode Delay timer of before line | 3 sec |
|
|
|
|
| 0 sec | 1 |
|
|
| connect |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2 | Auto Dial Mode Delay timer of after line | 3.6 sec |
|
|
|
|
| 3 sec | 0 |
|
|
| connect |
|
|
|
|
|
|
|
|
|
SW |
|
|
|
|
|
|
|
|
|
|
|
3 | Dial mode | Tone |
|
|
|
|
| Pulse | 1 | OPTION | |
l |
|
|
|
|
|
|
|
|
|
|
|
4 | Pulse → Tone change function by key | Enable |
|
|
|
|
| Disable | 1 |
| |
B4 |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
| |
5 | Dial pulse make/break ratio (%) | 40/60 |
|
|
|
|
| 33/67 | 1 |
| |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| 6 | Reserved |
|
|
|
|
|
|
| 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 7 | Reserved |
|
|
|
|
|
|
| 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 8 | Reserved |
|
|
|
|
|
|
| 0 |
|
|
|
|
|
|
|
|
|
| |||
| 1 | DTMF signal transmission level (Low) |
| Binary input |
|
| 0 |
| |||
| 2 |
| No. = | 16 | 8 | 4 | 2 | 1 |
| 1 |
|
SW | 3 |
|
| 1 | 2 | 3 | 4 | 5 |
| 0 |
|
4 |
|
| 0 | 1 | 0 | 1 0 (0.5 x 12 = | 1 |
| |||
l |
|
|
| ||||||||
5 |
|
|
|
|
|
|
|
| 0 |
| |
B5 |
|
|
|
|
|
|
|
|
| ||
| 6 | Reserved |
|
|
|
|
|
|
| 0 |
|
| 7 | Reserved |
|
|
|
|
|
|
| 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 8 | Reserved |
|
|
|
|
|
|
| 0 |
|
2 – 6